Documentation

C.3 Non-compartmental analysis, bioavailability and dose proportionality

Non-compartmental analysis, bioavailability and dose proportionality

What you will learn

  • Find the sources of the trapezoid rules, the dose-proportionality criterion and the two one-sided tests.
  • Compute the acceptance band for a slope from the dose range, as Smith et al. define it.
  • Decide a proportionality interval from a band.

Prerequisites: Chapter 14. The entries are written in the form authors, title, journal, year, volume(issue):pages, DOI; the first line of each entry is the citation, and the second says what the source gives and where the book uses it.

A short page, because non-compartmental analysis rests on few methods. The papers cover how an area is computed from a profile, how dose proportionality is decided (an interval against a band), and how bioavailability is judged by the two one-sided tests. Chapters 14 and 15 apply them.

This page has 5 entries.

Areas under the curve

  • [Yeh 1978] Yeh KC, Kwan KC. A comparison of numerical integrating algorithms by trapezoidal, Lagrange, and spline approximation. J Pharmacokinet Biopharm. 1978;6(1):79–98. doi:10.1007/bf01066064 What it gives: Compares the trapezoidal rule with higher-order integration of a concentration–time curve and shows where the linear trapezoid overestimates a falling curve. Used in: Chapter 14; A.15.

  • [Purves 1992] Purves RD. Optimum numerical integration methods for estimation of area-under-the-curve (AUC) and area-under-the-moment-curve (AUMC). J Pharmacokinet Biopharm. 1992;20(3). doi:10.1007/bf01062525 What it gives: Compares integration rules for the AUC and the AUMC and supports a logarithmic rule on the declining part of the curve. Used in: Chapter 14; A.15.

Dose proportionality

  • [Smith 2000] Smith BP, Vandenhende FR, DeSante KA, Farid NA, Welch PA, Callaghan JT, Forgue ST. Confidence interval criteria for assessment of dose proportionality. Pharm Res. 2000;17(10):1278–1283. doi:10.1023/a:1026451721686 What it gives: Proposes the power model for dose proportionality and a decision from the confidence interval of its slope against a band, not from a test of the slope. Used in: Chapter 15; B.5.

  • [Hummel 2009] Hummel J, McKendrick S, Brindley C, French R. Exploratory assessment of dose proportionality: review of current approaches and proposal for a practical criterion. Pharm Stat. 2009;8(1):38–49. doi:10.1002/pst.326 What it gives: Reviews the approaches to dose proportionality and proposes a practical criterion based on the ratio of exposures across the dose range. Used in: Chapter 15.

Bioavailability and equivalence

  • [Schuirmann 1987] Schuirmann DJ. A comparison of the two one-sided tests procedure and the power approach for assessing the equivalence of average bioavailability. J Pharmacokinet Biopharm. 1987;15(6):657–680. doi:10.1007/bf01068419 What it gives: The two one-sided tests procedure for equivalence, the basis of the interval-inside-a-band decision for bioavailability. Used in: Chapter 15; B.5.

Three numbers, three papers

Illustration, not a study result.

The trapezoid. For the profile of page A.15, the linear rule gives \(\mathrm{AUC}_{\text{last}}=64.200\) and the linear-up, log-down rule \(61.334\): the linear rule overestimates by \(2.87\) (4.7 %), nearly all of it in the long, falling final segment. Yeh and Kwan 1978 and Purves 1992 are the sources for why.

The band for the slope. In the power model \(\ln(\text{exposure})=a+b\ln(\text{dose})\), Smith et al. 2000 turn an acceptance band \((\theta_L,\theta_U)=(0.80,\ 1.25)\) for the dose-normalised exposure into a band for the slope: \(\bigl(1+\ln\theta_L/\ln r,\ 1+\ln\theta_U/\ln r\bigr)\), where \(r\) is the ratio of the highest to the lowest dose. For a 10-fold dose range (\(r=10\)) the band is \((0.903,\ 1.097)\); for a 4-fold range, \((0.839,\ 1.161)\); for 8-fold, \((0.893,\ 1.107)\). A confidence interval for the slope of \((0.95,\ 1.05)\) lies inside the 10-fold band (proportionality supported); \((0.88,\ 1.04)\) straddles its lower edge (inconclusive). The narrower the dose range, the wider the band, because the same exposure ratio spans less of the dose range.

The two one-sided tests. For a ratio of \(0.95\) with a 90 % confidence interval \((0.88,\ 1.03)\), both one-sided tests at the 5 % level pass, because the interval lies inside \((0.80,\ 1.25)\): Schuirmann 1987.

Review checklist

  • Do you state the integration rule behind an AUC, and the dose ratio behind a band?
  • Is a proportionality or an equivalence decision made from an interval and a band?

See the previous page, overview, the next page and the A–Z lookup.