Documentation

11.12 Values, types and missingness: VAL01–VAL10

Value checks ask whether each token can be interpreted safely, not whether the whole record is scientifically coherent.

IDs Rule
VAL01–VAL02 special items numeric; other text explicitly DROPped
VAL03–VAL04 missing markers and decimal notation compatible
VAL05 ID and TIME always present
VAL06 no undeclared numeric sentinel codes
VAL07–VAL08 finite, plausible magnitude, no field over 24 characters
VAL09 numeric IDs are whole, ≤15 digits and remain distinct
VAL10 every column has at least one value

Missing is not zero

Defaults recognize blank or . as missing for QC purposes. Strings such as NA, NULL, NAN, - and ND are reported because NM-TRAN cannot read them as intended numeric missing values. A blank DV on an observation can later become a fitted zero in NONMEM conventions; REC04 catches that record-level consequence.

Sentinels such as -99 and 99999 are numeric, so a parser accepts them. VAL06 searches configured sentinels to stop them entering ranges, covariate summaries or likelihoods as real measurements.

ID precision

Identifiers like 001 and 1 become the same numeric ID. Very long integer strings can lose precision. Preserve original identifiers in a DROP column and create a controlled numeric analysis ID with a documented mapping.

Common mistakes

  • Replacing all missing values with zero.
  • Declaring a genuine -99 measurement as a sentinel without context.
  • Assuming text subject IDs will work because they are unique.
  • Ignoring an entirely empty “reserved” column.

Checklist

  • Define allowed missing markers and sentinels.
  • Verify decimal point and absence of thousands separators.
  • Create and retain an ID mapping when renumbering.
  • Review field length and magnitude in source units.

Further reading