22.13 Exponential, linear, standardized-linear, and spline forms
The exponential form is
P = TVP × exp(theta × (X-reference))
It stays positive and interprets theta as log-parameter change per covariate unit. Scale X deliberately because a per-one-unit coefficient may be awkward or numerically small.
The linear form is
P = TVP × (1 + theta × (X-reference))
Theta is fractional change per unit, but the factor can cross zero. nlmx gives draft THETA bounds that keep it positive over the observed range.
standardized_linear uses an exponential factor with (X-reference)/SD, making theta correspond to a one-SD contrast and improving comparability across covariates. Its interpretation depends on the SD definition and analysis population.
The restricted cubic spline form uses configured degrees of freedom/knots and is more flexible. Flexibility increases degrees of freedom, overfitting risk, data requirements, and interpretation burden. Draft spline code may require careful hand confirmation.
Linear and exponential forms have the same local slope at theta = 0, so a score test cannot distinguish them. Use refit comparison when form selection matters. Over a narrow X range, even refits may be practically indistinguishable.
Choosing among flexible forms
Choose the simplest form that represents the anticipated biology across the supported range. Exponential forms guarantee a positive multiplier and express a constant change on the log-parameter scale. Linear forms are easy to read locally but can cross zero outside the observed range. Standardization changes coefficient units and can help numerical conditioning, while splines can reveal nonlinearity at the cost of more degrees of freedom and less stable tails. Compare fitted curves, not coefficient values across unlike parameterizations. For every candidate, plot the multiplier over the data range, mark the reference and percentiles, and inspect sparse regions where a flexible curve may be controlled by very few subjects.
Common mistakes
- Comparing exponential theta across different units.
- Allowing a linear factor to become nonpositive outside support.
- Calling standardized coefficients unit-free clinical effects.
- Selecting splines with sparse tails.
- Using score p-values to distinguish linear and exponential forms.
Checklist
- Scale and center X deliberately.
- Check positivity over observed and intended ranges.
- Match complexity to data support.
- Use refits for meaningful form comparison.
- Translate the final curve into clinical contrasts.
Further reading
Continue with form comparison, positivity, and Chapter 23’s candidate construction.