Documentation

14.16 AUMC, mean residence time, and steady-state volume

The area under the first moment curve, AUMC, integrates time multiplied by concentration. It gives later concentrations more leverage than ordinary AUC:

AUMC = integral of t × C(t) with respect to t

For a finite interval, nlmx applies the selected linear or logarithmic integration convention to the first moment. Under linear trapezoids, the segment is the trapezoid of t × C. Under logarithmic decline, nlmx uses the corresponding exact exponential integral rather than merely applying a log trapezoid to transformed endpoints.

The infinite tail is

AUMCinf = AUMClast + Tlast × Clast / lambda_z + Clast / lambda_z²

with the predicted-Clast variant using the terminal regression prediction. Because lambda_z appears squared, AUMCinf and its descendants can be especially sensitive to an unstable terminal slope.

Mean residence time

Mean residence time is an area ratio:

MRTlast = AUMClast / AUClast
MRTinf  = AUMCinf / AUCinf

For an intravenous bolus, MRTinf estimates the average time molecules reside in the body under linear assumptions. For a constant-rate infusion, input itself consumes time, so nlmx applies the standard correction MRTinf − infusion_duration/2. A negative or implausible corrected value signals incompatible data, timing, or assumptions and should not be “fixed” by taking an absolute value.

Steady-state volume

For intravenous data, steady-state volume is derived as

Vss = CL × MRT

Vss describes distribution at steady state and is conceptually different from terminal volume Vz. nlmx does not label an extravascular CL/F × MRT result as Vss because absorption contributes to residence time and F is unknown. A structural model may estimate other volumes, but they should not be substituted into an NCA table.

These quantities form a dependency chain: observations → AUC/AUMC → lambda_z tail → MRT → Vss. A warning at an early step propagates even when the final number appears smooth.

Common mistakes

  • Treating AUMC as AUC multiplied by the last time.
  • Forgetting the infusion-duration correction.
  • Comparing Vss with Vz as if they were interchangeable.
  • Reporting extravascular Vss without accounting for absorption.

Checklist

  • Confirm the AUMC integration convention.
  • Recalculate both terms in the infinite AUMC tail.
  • Apply route-appropriate MRT interpretation.
  • Verify infusion duration and time units.
  • Trace all terminal-slope diagnostics into MRT and Vss.

Further reading

Review AUMC integration, route-specific profile starts, and parameter dependencies.