B.5 Terms of non-compartmental analysis and exposure–response
What you will learn
- Read every quantity of an NCA table — Cmax, Tmax, AUClast, AUCinf, \(\lambda_z\), half-life, CL/F, Vz/F — and say how it is computed from the profile.
- Say when AUCinf may and may not be reported, and what the extrapolated percentage tells you.
- Judge dose proportionality and relative bioavailability with the right words.
- Name the six kinds of response of an exposure–response analysis, and the model that goes with each.
Prerequisites: B.1. The working detail is in Chapters 14–15 (NCA) and Chapters 32–33 (exposure–response); the formulas are on pages A.15 and A.17.
Non-compartmental analysis
Non-compartmental analysis (NCA) summarises a concentration–time profile without a structural model: it reads the peak from the data, integrates the area with trapezoids, and describes the tail by a straight line on the log scale. It needs rich data from each subject (page B.1).
- Cmax — the highest observed concentration. Tmax — the time at which it is observed. Both are read from the data, so they depend on the sampling times.
- AUC (area under the curve) — the integral of concentration over time, the measure of total exposure.
- Trapezoidal rule — approximating the area between two samples. The linear rule uses a straight line between them; the logarithmic rule uses a straight line between their logarithms and is the better description of a falling profile. The default described in the chapters is linear where the profile rises and logarithmic where it falls (linear-up, log-down). Where: Chapter 14.
- AUClast — the area from the first sample to the last quantifiable one. It uses only observed data.
- Terminal slope (\(\lambda_z\), lambda-z) — the rate constant of the terminal log-linear phase, the negative of the slope of \(\ln C\) against \(t\) over a chosen window of the last points. Terminal half-life — \(\ln2/\lambda_z\).
- Window selection — choosing how many of the last points define \(\lambda_z\); the program tries windows, keeps those that fit about equally well, and takes the one with the most points (page A.15); the reader checks it. The window is a judgement and is reported. Where: Chapter 14.
- AUCinf (\(\mathrm{AUC}_{0\text{–}\infty}\)) — AUClast plus the extrapolated tail, \(C_{\text{last}}/\lambda_z\). The extrapolated percentage is the tail as a share of AUCinf. A large share (a common warning level is 20 %) means the result depends on the extrapolation more than on data, and AUCinf should not be quoted.
- AUMC and MRT — the area under the first-moment curve (concentration times time), and the mean residence time, \(\mathrm{AUMC}/\mathrm{AUC}\).
- Apparent clearance (CL/F) — dose divided by AUCinf for an oral dose, \(\mathrm{CL}/F=D/\mathrm{AUC}_\infty\). Apparent volume (Vz/F) — \(\mathrm{CL}/F\big/\lambda_z\). The "apparent" is because the fraction absorbed \(F\) is unknown with oral data alone.
- Steady-state quantities — over a dosing interval \(\tau\) at steady state: AUC\(\tau\) (the area within the interval), the average concentration \(C_{\text{avg}}=\mathrm{AUC}_\tau/\tau\), the trough and peak, and the fluctuation of the concentration around its average. AUCinf is not reported at steady state: the interval's area already equals the single-dose AUCinf. Where: Chapter 15.
- Dose proportionality — whether exposure rises in proportion to dose. It is judged with the power model, \(\ln(\text{exposure})=a+b\ln(\text{dose})\): a slope \(b=1\) is proportional. The conclusion rests on the interval of the slope against an acceptance band, not on the point estimate (it is supported if the interval lies inside the band, rejected if it lies outside, inconclusive if it straddles an edge). Where: Chapter 15.
- Relative bioavailability — the ratio of the dose-normalised exposures of two formulations or routes, \(F=\dfrac{\mathrm{AUC}_{\text{test}}/D_{\text{test}}}{\mathrm{AUC}_{\text{ref}}/D_{\text{ref}}}\). A crossover design gives each subject both treatments in separate periods, with a washout between them long enough that none of the first drug remains. Where: Chapter 15.
- BLQ in NCA — below-limit values are set by a stated rule (before the first quantifiable value, between values, after the last).
- Sparse sampling — each subject has too few samples for a full individual NCA. The sparse study of Chapter 41 supports only Cmax, Tmax and AUClast, and no AUCinf.
Exposure–response
An exposure–response (ER) analysis relates a measure of exposure to an outcome, so as to answer "how much exposure is needed, and how much is too much?".
- Exposure metric — the exposure number used as the predictor: AUC, average concentration, trough, peak. Which one is right depends on the mechanism; the choice is part of the analysis. Where: Chapter 32.
- Response (endpoint) — the outcome. Six kinds are analysed, each with a matching model:
| Kind of response | Example | Model family |
|---|---|---|
| binary | responder / non-responder | logistic regression |
| count | number of events per subject | count regression (Poisson-type) |
| ordinal | a graded scale (none, mild, severe) | cumulative-logit (proportional-odds) model |
| continuous | change in a biomarker or score | linear or Emax model |
| time-to-event | time to progression or death | Kaplan–Meier curve, proportional-hazards model |
| longitudinal | a repeated measure over time | a model over time with exposure as a predictor |
- Link function — the transformation tying the predictor to the mean of the response. The logit link turns a probability into log-odds: \(\mathrm{logit}\,p=\ln\bigl(p/(1-p)\bigr)\).
- Odds and odds ratio — \(p/(1-p)\), and the ratio of odds for two exposures. A probability \(p=0.2\) is odds \(0.25\) and log-odds \(-1.386\); an odds ratio of \(2\) per unit of exposure moves the odds to \(0.5\), a probability of \(0.333\).
- Emax model — an effect that rises (or falls) with exposure and saturates: \(E=E_0+E_{\max}C/(EC_{50}+C)\), with the baseline \(E_0\), the maximum change \(E_{\max}\) and the exposure \(EC_{50}\) at half of it. Adding a Hill coefficient changes how steeply it rises. Where: Chapter 32.
- Hazard and hazard ratio — the instantaneous rate of an event and the ratio of rates; a Kaplan–Meier curve estimates survival without a model and handles censoring (subjects who leave the study event-free).
- Placebo — the reference group with no active exposure; the benefit over placebo and the difference between active exposures are different questions, and an analysis can answer one and not the other. Where: Chapter 33.
- Exposure group (quartile, tertile) — subjects binned by exposure to show the shape of the relationship without a model.
- Unadjusted and adjusted — an analysis without, or with, covariates in the model. Covariates can change the interval more than the estimate.
- Confounding by dose or severity — a relationship between exposure and response that arises because a third factor (a sicker patient clears the drug differently, or is given a different dose) drives both. ER is an association and does not by itself show that changing exposure changes the response.
- Delta method — an approximation of the standard error of a function of the estimates, such as the change in effect between two exposures (page A.12).
Two worked examples
Illustration, not a study result.
An NCA profile read as a table. A 100 mg oral dose gives concentrations of \(0,\ 3.1,\ 5.4,\ 6.8,\ 5.5,\ 3.3,\ 2.0,\ 0.45\) mg/L at \(0,\ 0.5,\ 1,\ 2,\ 4,\ 8,\ 12,\ 24\) h (the profile of page A.15). Cmax is \(6.8\) at Tmax \(=2\) h. With linear-up, log-down, AUClast \(=61.33\) mg·h/L (the all-linear rule gives \(64.20\), which overestimates the falling part by 4.7 %). The last four points give \(\lambda_z=0.1250\) h\(^{-1}\) and a half-life \(\ln2/0.1250=5.55\) h. The tail is \(0.45/0.1250=3.60\), so \(\mathrm{AUC}_\infty=64.94\), of which \(3.60/64.94=5.5\,\%\) is extrapolated: acceptable. Then \(\mathrm{CL}/F=100/64.94=1.540\) L/h and \(V_z/F=1.540/0.1250=12.3\) L. Relative to an intravenous reference of \(50\) mg with \(\mathrm{AUC}=40.0\), the bioavailability is \((64.94/100)/(40.0/50)=0.81\).
An exposure–response curve read at two places. An Emax model with \(E_{\max}=-10\) and \(EC_{50}=2\) falls by \(2.67\) units between exposures \(1\) and \(3\), but by only \(0.24\) units between \(10\) and \(12\). A single "effect per unit of exposure" for the whole range would be wrong in both places, which is why the effect between two exposures is stated with both exposures and an interval from the delta method.
Review checklist
- For each NCA quantity, do you know the rule or window that produced it, and have you looked at the extrapolated percentage?
- At steady state, or in a sparse study, do you refrain from reporting AUCinf?
- Is a dose-proportionality statement made from an interval and a band, not from a slope alone?
- For an ER analysis, do you name the metric, the type of response, the model, and whether the effect is over placebo or between active exposures?
Navigation
See the previous page, the overview and the next page, the nlmx operating vocabulary.