37.15 Noncompartmental-analysis settings: purpose, structure, and workflow
.nca is the settings format for nca. It defines profile construction, BLQ handling, integration, terminal-slope selection, interval rules, summaries, comparisons and figures. The template snapshot used here was generated by nlmx 4.16.2; its SHA-256 is 7c8bfeadf140d725ba0f245530166027b7bbc33e1fe68dc3b61baee1795cfdeb.
Why this file matters
Profile boundaries, dose interpretation, BLQ policy and lambda-z acceptance rules directly affect reported exposure parameters. Treat the file as controlled analysis source. A reviewer should be able to connect each active value to a design decision, data convention, method choice, output requirement or operational guardrail.
Generate and begin safely
nlmx nca --print-config study.nca
nlmx nca -c study.nca --output disposable-review
For .covar, generate the reference with nlmx schema --format toml and save it with the required extension. For every format, compare command-specific help before relying on the generic example above; commands differ in positional inputs, validation modes and whether --output is appropriate.
Template map
The snapshot represents 107 unique dotted key paths across 14 tables or top-level groups. Commented assignments are possibilities or examples; uncommented assignments form the generated example. The next page catalogs every represented key.
| Table | Unique keys represented | Review focus |
|---|---|---|
data |
20 | values and interactions inside this settings group |
analysis |
6 | values and interactions inside this settings group |
blq |
1 | values and interactions inside this settings group |
auc |
5 | values and interactions inside this settings group |
lambda_z |
14 | values and interactions inside this settings group |
lambda_z.overrides[] |
7 | values and interactions inside this settings group |
units |
4 | values and interactions inside this settings group |
summary |
3 | values and interactions inside this settings group |
dose_proportionality |
4 | values and interactions inside this settings group |
comparison |
5 | values and interactions inside this settings group |
figures |
19 | values and interactions inside this settings group |
plots |
9 | values and interactions inside this settings group |
plots.colors |
5 | values and interactions inside this settings group |
output |
5 | values and interactions inside this settings group |
Important interactions
- Verify one profile per intended subject-period-occasion before reading parameters.
- State linear-up/log-down or alternative integration and BLQ rules in methods.
- Review lambda-z points and adjusted R-squared rather than accepting half-life automatically.
- Dose proportionality and group comparisons need prespecified reference and model assumptions.
Novice workflow
First identify the input population and artifact version. Second, delete or leave commented every option you do not intend to control. Third, edit one table at a time and keep short comments explaining study-specific values. Fourth, run into a new disposable folder and verify resolved inputs, paths, warnings and output count. Fifth, compare the result with the scientific question and expected behavior. Finally, retain the settings, command transcript and reviewed outputs together.
What validation can and cannot prove
Parsing proves that TOML syntax and recognized keys are acceptable. Command validation may prove that referenced data and values satisfy implemented checks. Neither proves that the selected population, endpoint, method, threshold or model is scientifically justified. That judgment belongs in the analysis plan and review record.
The exact generated snapshot is available at ncadocuments/ch37/reference/templates/nlmx.nca.
Navigation
See the previous page, next page, and complete settings reference.