Documentation

37.15 Noncompartmental-analysis settings: purpose, structure, and workflow

Chapter 37.15 visual
Settings reference workflow

.nca is the settings format for nca. It defines profile construction, BLQ handling, integration, terminal-slope selection, interval rules, summaries, comparisons and figures. The template snapshot used here was generated by nlmx 4.16.2; its SHA-256 is 7c8bfeadf140d725ba0f245530166027b7bbc33e1fe68dc3b61baee1795cfdeb.

Why this file matters

Profile boundaries, dose interpretation, BLQ policy and lambda-z acceptance rules directly affect reported exposure parameters. Treat the file as controlled analysis source. A reviewer should be able to connect each active value to a design decision, data convention, method choice, output requirement or operational guardrail.

Generate and begin safely

nlmx nca --print-config study.nca
nlmx nca -c study.nca --output disposable-review

For .covar, generate the reference with nlmx schema --format toml and save it with the required extension. For every format, compare command-specific help before relying on the generic example above; commands differ in positional inputs, validation modes and whether --output is appropriate.

Template map

The snapshot represents 107 unique dotted key paths across 14 tables or top-level groups. Commented assignments are possibilities or examples; uncommented assignments form the generated example. The next page catalogs every represented key.

Table Unique keys represented Review focus
data 20 values and interactions inside this settings group
analysis 6 values and interactions inside this settings group
blq 1 values and interactions inside this settings group
auc 5 values and interactions inside this settings group
lambda_z 14 values and interactions inside this settings group
lambda_z.overrides[] 7 values and interactions inside this settings group
units 4 values and interactions inside this settings group
summary 3 values and interactions inside this settings group
dose_proportionality 4 values and interactions inside this settings group
comparison 5 values and interactions inside this settings group
figures 19 values and interactions inside this settings group
plots 9 values and interactions inside this settings group
plots.colors 5 values and interactions inside this settings group
output 5 values and interactions inside this settings group

Important interactions

  • Verify one profile per intended subject-period-occasion before reading parameters.
  • State linear-up/log-down or alternative integration and BLQ rules in methods.
  • Review lambda-z points and adjusted R-squared rather than accepting half-life automatically.
  • Dose proportionality and group comparisons need prespecified reference and model assumptions.

Novice workflow

First identify the input population and artifact version. Second, delete or leave commented every option you do not intend to control. Third, edit one table at a time and keep short comments explaining study-specific values. Fourth, run into a new disposable folder and verify resolved inputs, paths, warnings and output count. Fifth, compare the result with the scientific question and expected behavior. Finally, retain the settings, command transcript and reviewed outputs together.

What validation can and cannot prove

Parsing proves that TOML syntax and recognized keys are acceptable. Command validation may prove that referenced data and values satisfy implemented checks. Neither proves that the selected population, endpoint, method, threshold or model is scientifically justified. That judgment belongs in the analysis plan and review record.

The exact generated snapshot is available at ncadocuments/ch37/reference/templates/nlmx.nca.

See the previous page, next page, and complete settings reference.