Documentation

24.41 Comparing posterior, frozen, and SCM evidence

The three engines answer different questions. Frozen asks whether a local nuisance-adjusted score moves away from zero at the base solution. Posterior asks whether ETA–feature signal is repeatedly selected across posterior draws, subject resamples, and learners. SCM asks whether full model refits support stepwise likelihood-ratio additions/removals.

Evidence Strength Main vulnerability
Frozen score Fast local likelihood evidence Local approximation and information adjustment
Posterior stability Robustness to subject/posterior/algorithm perturbation Two-stage shrinkage, learner and resampling dependence
SCM refit Direct conditional likelihood comparison Computational cost and path dependence

In the teaching model, frozen retained V–WT and called both CL effects uncertain. Posterior retained V–WT and CL–WT, calling CL–EGFR uncertain. SCM retained all three true effects. Both fast methods correctly rejected null SEX relationships. This pattern supports escalation of uncertain CL effects rather than declaring a contradiction.

Agreement strengthens confidence but does not prove truth. Disagreement should be decomposed into effect size, correlation, local versus refit behavior, shrinkage, probability design, and thresholds. Do not force a majority vote. Define whether final candidates come from a union, intersection, or scientifically adjudicated set, then jointly refit and diagnose it.

Common mistakes

  • Comparing p-values and probabilities as the same scale.
  • Calling SCM an unquestionable gold standard when its path or fit is unstable.
  • Selecting the engine that matches expectations.
  • Averaging coefficients from separate methods.
  • Omitting rejected but clinically important effects.

Checklist

  • Label each estimand and evidence type.
  • Harmonize scope, equations, references, base, and final-refit likelihood.
  • Investigate disagreements rather than vote.
  • Apply prospective escalation/adjudication rules.
  • Report final model evidence separately.

Further reading

See Chapter 23, Chapter 23A when drafted, and Chapter 25 for the unified command workflow.