AUCtau and Cavg
AUCtau is the linear-trapezoidal integral over one steady-state dosing interval. Cavg is AUCtau/tau. When every subject/scenario uses the same interval, their ratios are identical; absolute values and units differ. With own regimens and varying tau, interpretation requires additional care.
For linear PK, AUC ratios should be compatible with inverse-clearance ratios at the same dose and bioavailability. Comparing them is a useful implementation check. Nonlinear models or dose-dependent bioavailability can break that shortcut.
Report the grid, interval, regimen, integration method, and exposure units. AUC precision includes the configured parameter or subject-bootstrap uncertainty but not unmodeled structural uncertainty.
Common mistakes
- Treating a forest ratio or reference-band class as covariate-selection evidence, causality, or an automatic dosing recommendation.
- Omitting the reference subject, uncertainty source, regimen, subgroup denominator, data support, or fitted-model diagnostics.
- Confusing parameter-uncertainty intervals, BSV ranges, and subject-bootstrap intervals because they share one graphic.
Page checklist
- The numerator, denominator, fitted model, covariate settings, and units are explicit.
- The interval source and clinical meaning are distinguished from BSV and selection uncertainty.
- Tables, resolved settings, commands, diagnostics, limitations, and confirmation evidence are retained.