27.10 Variability-corrected VPC
A pvcVPC first applies prediction correction and then scales deviations to a common simulated variability within each bin. Record-specific simulated SD is compared with the median SD in the bin, and both observed and simulated pc values receive the same variability transformation.
Novice translation
This topic changes three practical decisions in a predictive-check review. First, use --vpc-type pvcvpc or enable variability correction; --pvc with plain VPC selects the corrected form. Second, the method helps when residual or total variability changes strongly across predictions inside a bin. Third, read pvcVPC beside pcVPC because aggressive correction can make the transformed scale less intuitive. Keep those decisions separate: one defines what is simulated or summarised, another controls how evidence is displayed, and the last controls what conclusion the evidence can support. A reviewer should be able to reproduce each decision from the resolved settings and numerical tables, not infer it from the appearance of the figure.
What to understand
- Use
--vpc-type pvcvpcor enable variability correction;--pvcwith plain VPC selects the corrected form. - The method helps when residual or total variability changes strongly across predictions inside a bin.
- Read pvcVPC beside pcVPC because aggressive correction can make the transformed scale less intuitive.
Practical interpretation
If pcVPC and pvcVPC disagree materially, examine heteroscedastic residual structure, covariate-dependent IIV, and whether the bin combines incompatible uncertainty regimes.
Evidence to retain
For variability-corrected vpc, retain the issued command, vpc_settings.vpc, the source model/data/result identifiers, seed and replicate count, the relevant CSV/JSON fields, warnings and notes, and the exact figure used for interpretation. Record any sensitivity run that changed the conclusion. If an option was selected after seeing the data, label that analysis exploratory. This evidence separates a reproducible diagnostic decision from a visual impression and lets another pharmacometrician check counts, transformations, exclusions, and uncertainty assumptions.
Common mistakes
- Treating pvcVPC as automatically superior
- Omitting the transformation from captions
- Using it to conceal a variance model failure
Page checklist
- Justify variability correction
- Compare with pcVPC
- Inspect SD behavior
- Label transformed scale
Further reading
See previous page, next page, complete VPC command and settings index.