11.14 Infusion, repeated-dose, steady-state and duplicate checks: REC13–REC20

REC13 converts AMT/RATE to infusion duration and compares it with configured minimum/maximum limits. Set these limits in the same time units as TIME. RATE -1/-2 have modeled semantics and should not be interpreted as ordinary positive-rate infusions.

REC14–REC16 enforce the repeated-dose grammar: ADDL needs II, II belongs with ADDL or SS, these fields occur only on dose records, and SS must be an allowed code with a positive interval where required.

REC17 detects fully duplicated records, REC18 same-subject/time/compartment observations with different DV, and REC19 double doses at one time/compartment. REC20 inventories reset/other events for review.

Duplicate does not always mean wrong

Two bioanalytical replicates may be intentional, but they need a documented representation. Two identical dose rows may mean a true combined dose or an accidental copy. Do not delete one merely because a check named it. Verify the source and decide whether to retain separate records, average under a prespecified rule, or consolidate a dose.

Repeated-dose consequence

ADDL=2, II=0 does not define when the two added doses occur and is a failure. II=24 with neither ADDL nor SS is also suspicious because the interval has no operation to govern.

Drawing the implied regimen

Expand every ADDL record on paper or in a temporary review table: the explicit dose occurs at TIME, then additional doses occur at TIME + II, TIME + 2×II, and so on. Mark infusions by their AMT/RATE duration and show any reset before a dose. This simple timeline exposes overlaps, doses beyond the observation window and conflicts with explicit records. Do not add the implied doses to the controlled input merely for inspection; the model engine generates them from ADDL.

Common mistakes

  • Comparing infusion duration in hours to a threshold entered in minutes.
  • Adding II to silence REC14 without confirming regimen.
  • Automatically deduplicating observations.
  • Ignoring EVID 3/4 resets because they are rare.

Checklist

  • Derive infusion duration and verify units.
  • Reconstruct ADDL/II/SS regimen on a timeline.
  • Source-verify every duplicate or same-time conflict.
  • Review all reset/other events individually.

Further reading

See bolus and infusion, ADDL/II/SS and event/time case study.