Documentation

27.40 Worked LLOQ and BLQ panel

The BLQ workflow sets a fixed LLOQ of 0.2, uses nominal bins, and simulates 200 pcVPC replicates. Twenty-five of 480 observations are below LLOQ, all concentrated sufficiently to push the observed 5th percentile at 24 h below LLOQ.

Worked LLOQ and BLQ panel

Novice translation

This topic changes three practical decisions in a predictive-check review. First, the quantified pcVPC has one outside flag, while the BLQ panel directly compares observed and simulated percentages below 0.2. Second, nPC uses 455 quantified observations and explicitly notes exclusion of the 25 censored records. Third, the run demonstrates numeric LLOQ handling; a real M3 dataset may additionally require a BLQ flag and ICALL=4 model branch. Keep those decisions separate: one defines what is simulated or summarised, another controls how evidence is displayed, and the last controls what conclusion the evidence can support. A reviewer should be able to reproduce each decision from the resolved settings and numerical tables, not infer it from the appearance of the figure.

What to understand

  • The quantified pcVPC has one outside flag, while the BLQ panel directly compares observed and simulated percentages below 0.2.
  • NPC uses 455 quantified observations and explicitly notes exclusion of the 25 censored records.
  • The run demonstrates numeric LLOQ handling; a real M3 dataset may additionally require a BLQ flag and ICALL=4 model branch.

Practical interpretation

Interpret the BLQ and quantified panels together because either alone loses information about the low-concentration distribution.

Evidence to retain

For worked lloq and blq panel, retain the issued command, vpc_settings.vpc, the source model/data/result identifiers, seed and replicate count, the relevant CSV/JSON fields, warnings and notes, and the exact figure used for interpretation. Record any sensitivity run that changed the conclusion. If an option was selected after seeing the data, label that analysis exploratory. This evidence separates a reproducible diagnostic decision from a visual impression and lets another pharmacometrician check counts, transformations, exclusions, and uncertainty assumptions.

Common mistakes

  • Counting BLQ placeholders as DV
  • Forgetting NPC denominator change
  • Treating fixed LLOQ as record-specific

Page checklist

  • Confirm 25 censored
  • Read BLQ panel
  • Review 24-h percentile
  • Report NPC N

Further reading

See previous page, next page, complete VPC command and settings index.