15.8 BLQ, LLOQ, and censoring controls

BLQ handling has two stages: identify which records are BLQ, then choose how their concentrations enter NCA. Do not configure a replacement rule without verifying the identification stage.

Identifying BLQ observations

--lloq VALUE or [data] lloq marks concentrations below a numeric threshold. --blq-flag COLUMN or [data] blq uses a nonzero indicator column. A flag can coexist with an LLOQ; the recorded DV may then be zero or the reported limit. Without either definition, nlmx does not infer BLQ merely from a text convention in another column.

dv_log=true means DV contains natural-log concentrations. Confirm whether LLOQ is supplied on the concentration scale expected by the data reader; the safest practice is to inspect the resulting CONC, CONC_USED, and STATUS columns rather than assume transformation order.

Replacement rules

--blq-rule or [blq] rule accepts six rules:

  • zero;
  • missing;
  • lloq;
  • half-lloq;
  • tmax-zero-missing—default, zero before Tmax and missing from Tmax onward;
  • first-zero-mid-half-last-missing—zero before the first quantifiable sample, half-LLOQ internally, missing after the last quantifiable sample.

The processed value is recorded rather than silently overwriting source data. Terminal missingness can reduce lambda-z points or make AUCinf unavailable; that is expected evidence, not a reason to fabricate a tail.

Sensitivity and audit

For BLQ-heavy data, rerun a plausible alternative policy into a separate directory and compare profile count, Cmax/Tmax, AUClast, lambda-z availability, and extrapolated percentage. Keep the primary rule prespecified. Sensitivity analysis describes dependence on the convention; it should not be used to choose the most favorable treatment result.

Common mistakes

  • Treating zero, blank, negative, and flagged BLQ as interchangeable.
  • Giving a BLQ rule but no LLOQ or flag definition.
  • Removing BLQ rows with obs_filter before the audit table can describe them.
  • Allowing substituted terminal values to create an artificial lambda-z.

Checklist

  • Map LLOQ and/or BLQ flag explicitly.
  • Confirm the scale of DV and LLOQ.
  • Inspect CONC_USED and STATUS by profile position.
  • Count lost terminal points.
  • Run a documented sensitivity analysis when influential.

Further reading

See the six-rule theory page, profile audit output, and BLQ/sparse worked example.