Documentation

13.0 Complete eda command and option index

This page lists the command forms and options that eda actually consumes. The shared top-level help also exposes options for fitting, simulation, VPC, and other commands; those unrelated flags do not affect EDA merely because the global parser recognizes them.

Command forms

Purpose Command
Smallest run nlmx eda data.csv
Explicit input/output nlmx eda --data data.csv -o results/eda
Run from settings nlmx eda -c analysis.eda
List 24 plots and 10 tables nlmx eda --list-plots
Write the annotated template nlmx eda --print-config analysis.eda
Show installed help nlmx eda --help

Input precedence is positional dataset, then --data, then [data].file. Do not supply conflicting routes.

Dataset, mapping, and selection

Option Meaning
DATASET, --data FILE Headered delimited dataset.
--id-col, --time-col, --dv-col, --amt-col Core column names.
--evid-col, --mdv-col, --cmt-col, --rate-col Event and dose column names.
--addl-col, --ii-col, --ss-col Repeat/steady-state column names.
--mutate ASSIGNMENTS Sequential R-style column assignments before filters.
--filter EXPR Retain matching records.
--obs-filter EXPR Retain matching observations while preserving doses.
--group COLUMNS Colour groups; several columns form GROUP_ALL.
--lloq VALUE, --blq-flag COLUMN BLQ definition.
--dv-log DV is already natural-log concentration.
--tad-col, --nominal-time-col, --dvid-col Optional analysis columns.

eda auto-detects delimiter; the shared --delimiter flag is not an EDA control in the checked implementation.

Covariates and endpoints

Option Meaning
--covariates WT,AGE,SEX Plain covariate list; PARAM=COVS syntax is rejected.
--categorical SEX,RACE Force categorical classification.
--time-varying CRCL Declare changing covariates.
--stratify COLUMN Facet plots by a dataset column.
--pk-dvid VALUE, --pd-dvid VALUE Select PK and PD observation types.

Explicit continuous covariates and exclusions are configuration-only.

Standard analysis controls

Option Values/default
--eda-plots LIST IDs, names, categories, all or none; default all.
--eda-skip LIST Plots to omit.
--eda-tables LIST Table IDs/names/categories, all or none.
--eda-exposure Enable P18–P20 and T06–T07, off by default.
--eda-yscale both, linear, log; default both.
--eda-stat mean, median, geomean; default mean.
--eda-error sd, sem, ci95, iqr, p90, range, none.
--eda-x time, tad, nominal.
--time-unit, --conc-unit, --dose-unit Axis labels; no conversion is implied.
--individual-rows, --individual-cols Panels per individual-profile page, 1–20.
--list-plots Print catalogue and exit.

Output, figures, and execution

-c/--config FILE.eda, -o/--output DIR, --overwrite, --threads N, and --print-config FILE.eda control execution. Figure options are --no-plots, --no-svg, --no-caption, --plot-width, --plot-height, --plot-units in|cm|mm|px, --plot-dpi, --plot-base-size, --plot-format png|svg|both, --plot-colors, --plot-no-title, and --plot-no-legend.

Logging controls are --suppress-console 0|1, hidden alias --no-console, --log-file, --no-color, repeated -v/--verbose, -q/--quiet, and --license.

Configuration-only controls include smoothing/span, time bins, exposure interval, dose normalization, page/line/category caps, skipped tables, digits, HTML/JSON/CSV switches, HTML page cap, and all [[plot]]/[[table]] blocks.

Common mistakes

  • Assuming every global option changes EDA.
  • Using covariate-model PARAM=COVS syntax.
  • Forgetting exposure outputs are off by default.
  • Believing unit labels convert values.

Checklist

  • Start with this index and installed --list-plots.
  • Put durable choices in a version-controlled .eda file.
  • Retain the full command and executable version.
  • Recheck the inventory after upgrading nlmx.

Further reading

See first run, settings, and output bundle.