27.28 Covariance-based parameter draws and admissibility
With covariance-based uncertainty, nlmx draws correlated natural-scale parameters from an MVN centered at the final estimates. Fixed zero rows remain fixed and SAME ties remain tied. A draw is rejected when a THETA violates its bounds or when active OMEGA/SIGMA is not positive definite.
Novice translation
This topic changes three practical decisions in a predictive-check review. First, each replicate may redraw up to max_attempts, default 100; redraw totals are reported. Second, a non-positive-definite parameter covariance is replaced by a nearest positive-semidefinite matrix with a note, which must be reviewed. Third, natural-scale normal approximations can generate implausible states near bounds or for skewed uncertainty. Keep those decisions separate: one defines what is simulated or summarised, another controls how evidence is displayed, and the last controls what conclusion the evidence can support. A reviewer should be able to reproduce each decision from the resolved settings and numerical tables, not infer it from the appearance of the figure.
What to understand
- Each replicate may redraw up to
max_attempts, default 100; redraw totals are reported. - A non-positive-definite parameter covariance is replaced by a nearest positive-semidefinite matrix with a note, which must be reviewed.
- Natural-scale normal approximations can generate implausible states near bounds or for skewed uncertainty.
Practical interpretation
Inspect vpc_parameters.csv distributions, redraw frequency, bounds, variances, and correlations before accepting the bands.
Evidence to retain
For covariance-based parameter draws and admissibility, retain the issued command, vpc_settings.vpc, the source model/data/result identifiers, seed and replicate count, the relevant CSV/JSON fields, warnings and notes, and the exact figure used for interpretation. Record any sensitivity run that changed the conclusion. If an option was selected after seeing the data, label that analysis exploratory. This evidence separates a reproducible diagnostic decision from a visual impression and lets another pharmacometrician check counts, transformations, exclusions, and uncertainty assumptions.
Common mistakes
- Ignoring frequent redraws
- Assuming MVN is valid near boundaries
- Failing to archive COV
Page checklist
- Verify parameter order
- Review PSD note
- Inspect draws
- Report redraws
Further reading
See previous page, next page, complete VPC command and settings index.