13.11 Sampling, dosing, and BLQ plots: P08-P11
P08–P11 describe the design and observation process that produced the concentration profiles. Review these before interpreting PK shapes because irregular sampling, dose history, and censoring can create apparent biological patterns.
P08: sampling times
P08 shows histograms of time after first dose and time after dose. Peaks should resemble the intended schedule, while spread around peaks reflects operational timing. Unexpected times may represent unscheduled samples, unit problems, or incorrect dose linkage. Histograms do not preserve subject identity, so trace unusual bins back to records.
P09: observations per individual
P09 counts individuals by their number of observations. It reveals sparse subjects, unequal follow-up, and possible dropout. A subject with fewer observations is not necessarily erroneous, but the reason can affect exposure calculations and mixed-model information.
P10: dosing
P10 summarizes first dose and number of doses. Compare dose distributions with treatment arms and protocol design. Repeated-dose counts depend on correct EVID/AMT and ADDL interpretation; virtual ADDL doses and recorded dose rows should be reconciled.
P11: BLQ over time
P11 plots the fraction below LLOQ over time. It needs a scalar/column LLOQ or BLQ flag. MDV-marked BLQ samples can still contribute to the fraction. Late-time increases may be expected elimination, but group differences can also reflect assay limits, schedules, or exposure.
Common mistakes
- Calling nominal-time spread a protocol deviation without actual-time rules.
- Ignoring sparse subjects when comparing exposure.
- Counting dose rows without considering ADDL/II/SS semantics.
- Treating BLQ as ordinary missingness or zero concentration.
Checklist
- Compare sampling histograms with protocol windows.
- List subjects with atypical observation/dose counts.
- Verify dose derivation and repeated-dose semantics.
- State BLQ definition and handling.
- Trace unexpected bins to source records.
Further reading
See time and TAD QC, dosing QC, and BLQ QC.