41.6 Case 2: one oral dose, from profile to parameters
What you will learn
- Read an
ncasummary: the header, the rules line, the parameter table and the individual profiles.- Check three headline parameters against closed-form relations (Cmax at the peak sample, AUCinf = AUClast + Clast/λz, CL/F = dose / AUCinf).
- See why the terminal slope, the half-life and the extrapolated area are linked.
- Decide whether a set of exposure numbers is ready to be reported.
Prerequisites: Chapter 14 and Chapter 15 (non-compartmental analysis).
The question: what are the exposure parameters after a single oral dose, and can the numbers be trusted?
The evidence: the Chapter 15 bundle oral_single (documents/ch15): six subjects, 100 mg orally, 10 samples each from 0.25 to 48 h, settings oral_single.nca, outputs nca_summary.txt, nca_parameters.csv, nca_lambda_z.csv.
The rules line comes first
The summary announces, before any number, the rules that produced the numbers:
data 6 subjects (6 in the file), 60 observations, 0 below LLOQ, 6 dose records
route oral (extravascular) — 6 dose(s) go into another compartment than the observations (CMT 2): extravascular
profiles 6 analysed of 6 dosing intervals; terminal slope found in 6
rules AUC linear-up-log-down · BLQ tmax-zero-missing · λz best-fit (adjusted R² ≥ 0.7, ≥ 3 points) · τ/steady state auto
units dose mg · time h · concentration mg/L
Read it like a methods section. Linear-up, log-down means the trapezoid is linear while the concentration rises and logarithmic while it falls. Best-fit λz means the terminal slope is chosen from the last points by the best adjusted R², with at least three points and adjusted R² of at least 0.7. Route: extravascular is inferred because the dose goes into compartment 1 and the samples come from compartment 2. If any of those did not match your study, the numbers below would not either.
The headline numbers
| Parameter | Mean | CV % | Range |
|---|---|---|---|
| CMAX (mg/L) | 1.605 | 8.6 | 1.419 – 1.807 |
| TMAX (h) | 2 | 0 | 2 – 2 |
| AUCLAST (mg·h/L) | 19.595 | 8.6 | 17.331 – 22.057 |
| AUCINF_OBS (mg·h/L) | 19.773 | 8.6 | 17.488 – 22.257 |
| LAMZ (1/h) | 0.0999 | 0.0 | — |
| THALF (h) | 6.938 | 0.0 | — |
| AUC extrapolated (%) | 0.898 | 0.0 | — |
| CL/F (L/h) | 5.089 | 8.6 | 4.493 – 5.718 |
| VZ/F (L) | 50.937 | 8.6 | 44.975 – 57.241 |
Two features stand out before any calculation: the same CV of 8.6 % on every exposure measure and a CV of 0.0 % on λz, half-life and Tmax. In real data the half-life varies between subjects; here it does not. The six profiles are scaled copies of one another: the figure shows six curves with identical shape, offset on the log axis. This is a synthetic study, and the bundle's purpose is to show the machinery without noise, so the checks below can be done by hand.
Three checks you can do with a calculator
1. Half-life from the slope. t½ = ln 2 / λz = 0.6931 / 0.0999 = 6.938 h, as reported.
2. The extrapolated area. For subject 1, AUCinf = AUClast + Clast / λz. The summary gives AUClast = 17.331 and AUCinf = 17.488, so the extrapolated piece is 0.157 mg·h/L, about 0.9 % of the total (the table reports 0.898 %). Check Clast/λz: the smallest last concentration is 0.0157 at 48 h, and 0.0157 / 0.0999 = 0.157. ✔
3. Clearance from the dose. CL/F = dose / AUCinf = 100 / 17.488 = 5.718 L/h, the value printed for subject 1. And V_z/F = CL/F / λz = 5.718 / 0.0999 = 57.2 L, as printed. ✔
Three numbers, three closed-form relations, three agreements. When the shape of a report is right but a value is unfamiliar, this is how to find out whether the program or your expectation is wrong.
The meaning of the parameters
- CMAX and TMAX are observed: the highest sample and its time. With samples at 0.25, 0.5, 1, 2, 4… the true peak can lie between two samples, so TMAX = 2 h means "the highest of the samples", not "the peak was at 2 h".
- AUCLAST uses only the observed range (0 to 48 h); AUCINF adds the tail by extrapolating with λz. Reporting AUCINF is sound only if the extrapolated share is small (here 0.9 %); a common rule flags anything above 20 % (page 41.9 shows what happens when it is exceeded).
- CL/F and V/F are "apparent": after an oral dose, the bioavailable fraction F is unknown, so only CL/F and V/F can be estimated. They are not clearance and volume.
- MRT is the mean residence time; for an oral dose MRTINF (10.83 h) includes the absorption phase.
Partial areas
The settings request partial areas, AUC_0_4 and AUC_0_12: mean 5.343 and 13.279 mg·h/L. Partial areas are not decorations. A 12-hour area is what a twice-daily regimen would accumulate, and the ratio 13.279/19.595 = 68 % says that two-thirds of the single-dose exposure happens in the first 12 hours.
The decision
| Question | Evidence | Decision | Reversible? |
|---|---|---|---|
| Are the exposure numbers ready to report? | nca_summary.txt: λz found in 6 of 6, R² = 1, 0.9 % extrapolated; three hand checks agree |
Yes. Report CMAX, AUCINF and CL/F with their rules line | yes |
What would have changed it: a terminal slope found in fewer than all profiles, an R² well below 1, or an extrapolated area above 20 %.
What this case does not show
It does not show noise. In a real study the six curves would cross, λz would vary by subject, and some profiles would carry flags. The next cases add those complications one at a time.
Review checklist
- Did you read the rules line before the numbers?
- Is t½ = ln 2 / λz in your output?
- Is the extrapolated fraction small enough for AUCINF to be reported?
- Do you call oral clearance and volume apparent (CL/F, V/F)?
Navigation
See the previous page, the next page and the complete case-study reference.