Documentation

14.8 AUMC and first-moment area

AUMC is the area under the first-moment curve: the integral of time multiplied by concentration. Late concentrations receive greater weight because of the factor t, so AUMC is more sensitive than AUC to terminal sampling and extrapolation.

For linear segments, the checked reference convention uses the trapezoid of tC. For logarithmic segments it integrates tC exactly under exponential interpolation. Units are concentration·time².

Observed and infinite moment

AUMCLAST ends at Tlast. With λz, the observed-Clast infinite moment is

AUMC∞ = AUMClast + Tlast·Clast/λz + Clast/λz²

A terminal-predicted Clast version is also possible. The Clast/λz² term makes AUMC∞ particularly sensitive to a small λz. A modest terminal-slope change can move MRT substantially even when AUC∞ changes little.

Relationship to MRT

Mean residence time is AUMC/AUC under route-specific conditions. MRTlast uses truncated quantities and is not interchangeable with MRT∞. For infusion, subtract half the infusion duration. For extravascular administration, MRT includes absorption time and should not be used as an IV disposition MRT for Vss.

Why convention and origin matter

A reference tool can match AUC closely yet differ more visibly in AUMC if its first-moment segment formula differs. Audit AUMC cumulatively, confirm squared time units, and retain full precision. A shifted time origin also changes AUMC and MRT even when ordinary AUC is unchanged; use time relative to the applicable dose.

Late samples receive the greatest time weight. A small concentration error at 48 hours may contribute more to AUMC than a larger absolute error near the peak, so terminal assay behavior and BLQ decisions deserve explicit sensitivity review.

Common mistakes

  • Confusing AUMC with AUC multiplied by a single time.
  • Ignoring the squared λz sensitivity in the terminal moment.
  • Comparing MRTlast and MRT∞ as equivalent.
  • Computing extravascular Vss from an absorption-contaminated MRT.

Checklist

  • Confirm AUMC segment convention.
  • Inspect terminal support before using AUMC∞.
  • Label observed versus predicted Clast versions.
  • Apply infusion correction where required.
  • Use MRT only for route-appropriate derivations.

Further reading

See MRT and Vss, extrapolation, and route rules.