Prerequisites and base-model readiness
SCM inherits every weakness of its base model. Before selection, verify that the structural and statistical model is scientifically credible, the dataset passes QC, parameter estimates are plausible, gradients are acceptably small, random effects are estimable, and the residual model is not hiding a trend. A covariate path should not be used to repair an incorrect compartment model or an unhandled data problem.
The input family must be unambiguous: control stream, estimates, covariance/correlation information when used, data, listing, and individual estimates must describe the same run. Prefer --model-dir plus --run-stem, or an explicit --files manifest. The SCM likelihood is evaluated by nlmx; it does not launch NONMEM merely because NONMEM-format files are inputs.
Record the base OFV, approximation, number of subjects/observations, parameter bounds, convergence status, covariance-step status, shrinkage, and key diagnostic findings. If nlmx's base objective materially differs from the reference engine, resolve or qualify that difference before using stepwise deltas as a cross-software claim.
Common mistakes
- Treating a stepwise p-value as clinical importance or causal proof.
- Reading a candidate comparison without its active model, convergence state, degrees of freedom, and exact threshold.
- Reporting only the terminal relationship list while discarding failed models, path decisions, configuration, and provenance.
Page checklist
- The scientific question, model identities, and comparison direction are explicit.
- Numerical validity is reviewed before interpreting statistical evidence.
- The result is linked to the complete trace and final joint-model diagnostics.