Documentation

8.6 ADVAN/TRANS support matrix

The ADVAN specification determines compartments, default dose/observation compartments, required PK variables, propagation method and stiffness mode.

ADVAN families mapped to propagation engines

Figure 8.5. Analytic, matrix-exponential and adaptive ODE paths share record execution semantics, but have different numerical assumptions and validation targets.

Table 8.2. Implemented ADVAN families

ADVAN Model Supported TRANS Engine
1 One compartment 1, 2 Analytic linear
2 One compartment + depot 1, 2 Analytic linear
3 Two compartments 1, 3, 4, 5, 6 Analytic linear
4 Two compartments + depot 1, 3, 4, 5, 6 Analytic linear
5, 7 General linear $MODEL Rate constants Matrix exponential
6 General nonlinear $DES — Dormand–Prince
8, 9 General nonlinear $DES — Rosenbrock stiff solver
10 One compartment, Michaelis–Menten — Nonlinear integration
11 Three compartments 1, 4, 6 Analytic linear
12 Three compartments + depot 1, 4, 6 Analytic linear
13 General nonlinear $DES — Automatic nonstiff-to-stiff switch
14, 15 General nonlinear $DES — Rosenbrock stiff solver

ADVAN numbers not listed are refused. TRANS defaults to 1 when omitted, which can be scientifically wrong if the $PK code assigns clearances and volumes. Make TRANS explicit for reviewed models.

Defaults

Classic ADVANs define compartment names and default compartments. Absorption models dose the depot and observe the central compartment. Non-absorption models dose and observe central. General models take order, DEFDOSE and DEFOBS from $MODEL, falling back to the first compartment when flags are absent.

Analytic does not mean closed-form only

Classic mammillary models have analytic eigen structures. General linear models and degenerate classic cases can use a matrix exponential. Both avoid time-step discretisation for constant coefficients over an interval, but event and parameter changes still split the timeline.

Comparison discipline

Match ADVAN, TRANS, compartment numbering and parameter names before comparing outputs. ADVAN4 TRANS4 and ADVAN3 TRANS4 do not share the same central compartment number because ADVAN4 includes a depot.

Common mistakes

  • Omitting TRANS and assuming clearance/volume mapping.
  • Comparing compartment numbers without accounting for a depot.
  • Calling every linear propagation path a hand-written closed form.

Checklist

  • Verify ADVAN/TRANS against this versioned matrix.
  • Confirm default dose and observation compartments.
  • Check the chosen engine and stiffness mode.

Further reading

See parameter mappings, linear propagation and $DES solvers.