Documentation

15.20 Parameter columns: identity, direct observations, exposure, and partial areas

nca_parameters.csv has one row per constructed profile, including skipped profiles. The first columns identify the analysis unit:

Column Meaning
ID Subject identifier.
GROUP Combined group label or all.
OCCASION Constructed dose number for the subject.
ROUTE extravascular, iv bolus, or iv infusion.
STEADY_STATE 1 when classified as steady state.
DOSE Profile dose before display/derivation context.
N_SAMPLES Usable sample count after processing.
INF_DURATION AMT/RATE for infusion when available.
TAU Dosing interval for steady-state metrics.

Direct concentration-time descriptors

TLAG describes initial delay under the implemented profile convention. C0 is the IV bolus time-zero value when available. CMAX and TMAX are the observed maximum and first time of that maximum; CMAX_D is dose-normalised Cmax. CMIN/TMIN apply to steady-state or interval interpretation. CLAST and TLAST identify the last positive usable observation, while CLAST_PRED is terminal-line prediction at Tlast.

Exposure columns

AUCLAST is observation-supported area to Tlast; AUCLAST_D is dose-normalised. AUCINF_OBS and AUCINF_PRED use observed and predicted Clast, and AUCINF_D is the dose-normalised infinite area convention. AUC_PCT_EXTRAP_OBS and _PRED quantify the respective tail percentages.

AUMCLAST, AUMCINF_OBS, and AUMCINF_PRED are first-moment areas. Their units contain squared time and they are more tail-sensitive than AUC.

Every configured partial interval appends a column such as AUC_0_4. The exact name derives from boundary formatting; read the header rather than assuming a hard-coded schema when windows change.

Audit principle

Direct descriptors can exist when terminal fields do not. Do not discard Cmax/AUClast simply because half-life is missing, and do not imply that AUCinf is equally observation-supported. Compare unrounded CSV values, not report formatting.

Common mistakes

  • Assuming Cmax is model-predicted rather than observed.
  • Treating Clast-predicted and observed variants as interchangeable.
  • Comparing dose-normalised fields when effective-dose conventions differ.
  • Hard-coding partial-column names without reading configured windows.

Checklist

  • Identify the profile key before comparing rows.
  • Separate observed, predicted, and extrapolated fields.
  • Verify dose-normalisation convention.
  • Check units for AUC versus AUMC.
  • Read flags and skips with every row.

Further reading

Continue with terminal and derived columns, steady-state/flag columns, and the formula index.