15.20 Parameter columns: identity, direct observations, exposure, and partial areas
nca_parameters.csv has one row per constructed profile, including skipped profiles. The first columns identify the analysis unit:
| Column | Meaning |
|---|---|
ID |
Subject identifier. |
GROUP |
Combined group label or all. |
OCCASION |
Constructed dose number for the subject. |
ROUTE |
extravascular, iv bolus, or iv infusion. |
STEADY_STATE |
1 when classified as steady state. |
DOSE |
Profile dose before display/derivation context. |
N_SAMPLES |
Usable sample count after processing. |
INF_DURATION |
AMT/RATE for infusion when available. |
TAU |
Dosing interval for steady-state metrics. |
Direct concentration-time descriptors
TLAG describes initial delay under the implemented profile convention. C0 is the IV bolus time-zero value when available. CMAX and TMAX are the observed maximum and first time of that maximum; CMAX_D is dose-normalised Cmax. CMIN/TMIN apply to steady-state or interval interpretation. CLAST and TLAST identify the last positive usable observation, while CLAST_PRED is terminal-line prediction at Tlast.
Exposure columns
AUCLAST is observation-supported area to Tlast; AUCLAST_D is dose-normalised. AUCINF_OBS and AUCINF_PRED use observed and predicted Clast, and AUCINF_D is the dose-normalised infinite area convention. AUC_PCT_EXTRAP_OBS and _PRED quantify the respective tail percentages.
AUMCLAST, AUMCINF_OBS, and AUMCINF_PRED are first-moment areas. Their units contain squared time and they are more tail-sensitive than AUC.
Every configured partial interval appends a column such as AUC_0_4. The exact name derives from boundary formatting; read the header rather than assuming a hard-coded schema when windows change.
Audit principle
Direct descriptors can exist when terminal fields do not. Do not discard Cmax/AUClast simply because half-life is missing, and do not imply that AUCinf is equally observation-supported. Compare unrounded CSV values, not report formatting.
Common mistakes
- Assuming Cmax is model-predicted rather than observed.
- Treating Clast-predicted and observed variants as interchangeable.
- Comparing dose-normalised fields when effective-dose conventions differ.
- Hard-coding partial-column names without reading configured windows.
Checklist
- Identify the profile key before comparing rows.
- Separate observed, predicted, and extrapolated fields.
- Verify dose-normalisation convention.
- Check units for AUC versus AUMC.
- Read flags and skips with every row.
Further reading
Continue with terminal and derived columns, steady-state/flag columns, and the formula index.