Documentation

11.18 Observation outliers, spikes and sampling: OBS06–OBS13

OBS06 compares concentrations with other subjects at similar time after dose. It requires both a robust-z threshold (default 4.5) and minimum fold separation (default 3), with at least eight observations per one of ten equal-count time bins. Dose normalization is on by default when dose levels differ.

OBS07 identifies isolated within-profile rebounds: a value more than the configured fivefold above both neighbors after the peak. These rules locate records for source review; they do not authorize deletion.

OBS08 checks predose concentrations against a tolerance. Nonzero values may indicate carryover, endogenous compound, incorrect time, missed dose history or contamination. Configure context instead of assuming zero.

OBS09–OBS10 check minimum observations and at least one quantifiable postdose value per subject. OBS11 checks declared DV scale. OBS12 inventories observation types, and OBS13 summarizes sampling design.

Why two outlier views

A population outlier may be smooth within one person's profile, and a within-profile spike may occur at a time where population variability is high. Review both, then check sample identity, collection time, dilution/reanalysis and assay flags.

Understanding why a rule did not run

Outlier checks need comparable observations. With too few values in a time bin, the robust reference is not reliable and the check may have little opportunity to flag. Mixed analytes, routes or dose levels can also broaden the comparison. Inspect CHECKED, comments, DVID configuration and dose normalization before concluding that the data contain no outliers. A visual profile and source review remain necessary even when the statistical rule passes.

Common mistakes

  • Deleting outliers because a robust rule flagged them.
  • Running the rule on mixed analytes without DVID.
  • Comparing doses without normalization when proportionality is expected.
  • Ignoring sparse subjects because the overall sample count is large.

Checklist

  • Review population and within-profile evidence separately.
  • Stratify by DVID/assay/group where appropriate.
  • Verify flagged samples against source and assay records.
  • Document retain/exclude decisions independently of the QC file.

Further reading

See sampling plot interpretation, BLQ/outlier case study and the planned diagnostics chapter.