14.21 Sparse, destructive, and irregular sampling

Standard individual NCA assumes that enough observations from one subject and one dose interval form a meaningful concentration-time profile. Sparse and destructive designs can violate that assumption. A row can still be integrated numerically, but the resulting number may not estimate an individual pharmacokinetic quantity.

Sparse individual profiles

With only a few samples per subject, Cmax may be missed, AUC intervals may span large unobserved regions, and terminal regression may be impossible. nlmx requires at least three usable observations for a basic profile and at least three eligible positive points for a terminal line by default. Passing a minimum count does not guarantee adequate design: three samples clustered near Tmax do not characterize late decline.

Naively pooling observations from different subjects into one “average subject” can create a curve no participant actually followed. Differences in dose time, absorption time, covariates, and missingness may distort both peak and terminal slope. nlmx's ordinary profile workflow is not a dedicated sparse-sampling or population NCA engine.

Destructive sampling

In animal studies, a different animal may contribute at each time because collection is terminal. Individual AUC and half-life cannot be calculated in the usual way. Analysis typically requires group-time means plus a variance method designed for destructive sampling, or a population model that represents between-animal variability. Treating each animal as if it had the entire composite curve understates the actual uncertainty.

Irregular schedules

Trapezoidal integration naturally handles unequal time gaps, but accuracy depends on what occurs inside each gap. A wide interval around the peak can understate Cmax and area; a wide terminal interval can dominate lambda_z. Treatment-dependent sampling times can create apparent treatment differences even when underlying kinetics are similar. Plot actual sample times and summarize time deviations rather than relying only on nominal labels.

Missingness also matters. If late samples are more often absent in subjects with low concentrations, estimable AUCinf and half-life form a selected subset. Report the number of profiles entering every endpoint, not only the original enrollment count.

Common mistakes

  • Calling a composite destructive-sampling curve an individual profile.
  • Assuming trapezoids remove bias from wide sampling gaps.
  • Comparing endpoints with different estimable populations without disclosure.
  • Using nominal time when actual time is available and materially different.

Checklist

  • Classify the design as rich, sparse, composite, or destructive.
  • Plot actual sampling times and gap sizes.
  • Count usable profiles separately for each endpoint.
  • Use a method that represents the design's uncertainty.
  • State when standard individual NCA is not appropriate.

Further reading

See profile construction, integration assumptions, and validation design.