33.29 Worked example: placebo correction and adjustment

Two analysis blocks subtract study-specific placebo means: one unadjusted and one adjusted for baseline covariates. Original values remain in the data output and subtraction means are exported. The adjusted E0 is a reference-subject intercept and need not stay at zero.
Command or configuration pattern
nlmx er -c data/er/06_placebo_correction.er -o placebo --overwrite
The relevant controls are: placebo_by STUDY; subtraction table; raw retained; unadjusted/adjusted blocks. Use the complete command and settings index for accepted values, defaults, CLI mappings, and settings-only controls.
A reliable operating sequence
- State the endpoint estimand, exposure metric/window/units, analysis population, adjustment set, and clinically useful contrast.
- Reconcile input rows, subjects, arms, exposure availability, endpoint information, and all endpoint-specific fields.
- Run the smallest useful specification first; inspect exclusions and eligible models before adding subgroups, selection, or bootstrap.
- Read absolute predictions and observed support alongside relative effects, information criteria, p-values, and diagnostics.
- Archive the command,
.erfile, mutated/used data, exclusions, transcript, tables, plots, report, version, and checksums.
How to read and review the result
Reconcile placebo subjects per study and inspect any overall-mean fallback. Compare corrected and uncorrected scientific conclusions. Mean subtraction does not remove confounding or turn individual-exposure association into a randomised effect.
For a novice, the safest reading order is er_summary.txt → er_analyses.csv → the analysis-specific exclusions and model table → effects/predictions → diagnostic plots → row-level data → report.html. The report is a presentation layer; the CSV/JSON files and transcript are the audit layer.
Quality-control questions
- Did the number of analysed subjects, events, categories, exposure groups, and visits match the specification?
- Were placebo, active zeros, missing values, filters, repeated rows, categories, offsets, censoring, and covariate references handled as intended?
- Were ineligible fits retained and explained rather than silently dropped or allowed to win?
- Does the reported contrast stay inside exposure support, and are its units and endpoint direction clear?
- Do diagnostics and sensitivities support the same decision, and are causal and transportability limits explicit?
Common failure modes
- Treating the best criterion or smallest p-value as a clinical conclusion.
- Reading an odds, rate, or hazard ratio without its exposure contrast and absolute outcome context.
- Overwriting an evidence directory before preserving the prior settings, log, and checksums.
Navigation
See the previous page, next page, and complete command and settings index.