Documentation

28.25 Metric interval and concentration source

Metric interval and concentration source

Metrics are calculated over one dosing interval beginning at a selected dose. last is the default; first or a numbered dose can be selected. Tau normally comes from II or generated dosing settings. For a supplied single-dose dataset without II, set [metrics] tau; in nlmx 4.14.3 the shared CLI --tau does not populate this sims setting.

Why this matters

This decision changes what population, random quantity, time interval, or numerical summary the command represents. For a novice, the safest habit is to write the question in one sentence before choosing an option, then verify that the resolved settings and output columns express that same question. For a reviewer, the important distinction is between what was assumed, what was randomly generated, what was calculated, and what can legitimately be concluded.

Detailed behavior

  • dense evaluates an error-free individual profile on a grid plus requested exact times.
  • sampled uses study sample times and can include EPS.
  • observed uses simulated DV after BLQ action.
  • COVERED=0 identifies an interval not fully covered rather than silently calling a partial AUC complete.

The subject-level table is the bridge between the design and the exposure result. Use it to check IDs, arms, population labels, age, sex, weight, dose, interval start, tau, ETA values, and added covariates. Use the metric table to check one row per subject and simulation, the requested metric columns, and COVERED. Use pooled and replicate summaries for different purposes: pooled rows describe all simulated subject outcomes, while replicate intervals describe how a finite simulated study result varies from study to study.

Example command or settings fragment

[metrics]
profile = 'observed'
interval = 'first'
tau = 24.0

Start with a small smoke run and inspect the transcript before scaling. For command-line work, quote expressions containing comparison signs, brackets, or commas as required by the shell. For a permanent analysis, prefer a settings file: it exposes settings-only controls, resolves paths relative to itself, rejects unknown keys, and is echoed in fully resolved form with the output.

Interpretation and quality control

State the profile source beside every metric. Dense CMAX estimates a model peak; sampled CMAX estimates the largest protocol sample; observed CMAX additionally contains residual error and censoring policy.

At minimum, reconcile the console summary with the CSV/JSON result, inspect warnings and notes, confirm subject and observation counts, verify requested groups and targets, and review the source model's applicability. A chart can reveal shape and subgroup patterns, but every reported number should come from the tables. If a result changes a decision, run a prespecified sensitivity for Monte Carlo stability, parameter uncertainty, population assumptions, and the metric-profile source.

Common mistakes

  • Mixing dense and observed metric interpretations
  • Ignoring COVERED
  • Relying on --tau for a supplied no-II design in 4.14.3

Also avoid overwriting a completed evidence folder merely to change styling. Create a new scenario directory or preserve the prior checksums so analytical changes remain distinguishable from presentation changes.

What to retain and report

  • the nlmx version, complete issued command, submitted settings, and resolved _settings.sims;
  • CTL, selected EXT, optional COV or parameter table, and supplied dataset or population-generation assumptions;
  • seed, subproblems, thread count, ETA/EPS and parameter-uncertainty policy;
  • metric interval, tau, profile source, grid, integration rule, group definitions, and target limits;
  • numerical tables, JSON, HTML, figures, transcript, checksums, warnings, sensitivities, and scoped interpretation.

See the previous page, next page, and complete sims command and settings index.