Documentation

14.18 Dose normalisation and dose proportionality

Dose normalisation helps compare exposure across dose levels when linear pharmacokinetics are plausible. A metric such as AUC or Cmax is divided by effective dose:

dose-normalised metric = metric / effective dose

Similar normalized values are compatible with dose-proportional exposure, but visual similarity is not a formal conclusion. Differences can arise from true nonlinearity, formulation, body-size imbalance, sampling coverage, BLQ handling, or random variability.

The power model

nlmx evaluates dose proportionality with the log-log power model when sufficient dose levels and profiles are available:

ln(PK metric) = ln(alpha) + beta × ln(dose) + error

Perfect proportionality corresponds to beta = 1. A confidence interval for beta expresses precision of the exposure-dose relationship over the observed range. With at least three usable profiles and at least two distinct dose levels, a fit can be attempted; a sparse design may be mathematically estimable yet too weak for a reliable clinical conclusion.

One common acceptance approach derives beta limits from a target exposure ratio such as 0.80 to 1.25 and the tested maximum-to-minimum dose ratio. Because the resulting interval depends on the dose range, it is not interchangeable with checking whether a conventional confidence interval merely contains 1. The protocol must state the criterion, confidence level, endpoint, and dose range.

Comparison methods and their required structure

Interpretation

The slope is an average relationship on the log scale, not proof that every adjacent dose pair is proportional. Curvature, saturation, or a threshold effect can be missed by a single slope. Plot raw and normalized metrics by dose, inspect residuals, and consider a model with lack-of-fit terms when the design supports it. Cmax and AUC may behave differently, so they require separate conclusions.

Dose proportionality is also not bioequivalence. It compares dose levels, whereas bioequivalence compares treatments or formulations at defined doses using a prespecified statistical design.

Common mistakes

  • Fitting the model to dose-normalised values instead of raw positive metrics.
  • Interpreting a nonsignificant departure from beta = 1 as proof of proportionality.
  • Ignoring the dose range used to derive acceptance limits.
  • Pooling endpoints or formulations without a prespecified model.

Checklist

  • Verify positive doses and positive PK metrics.
  • State the effective-dose convention.
  • Plot raw and normalized values.
  • Report beta, uncertainty, dose range, and criterion.
  • Examine curvature, imbalance, and influential profiles.

Further reading

Continue with bioavailability and group ratios, units and dose factors, and Chapter 15's output interpretation.