15.21 Parameter columns: terminal fit, clearance, volume, and MRT

The terminal block records the chosen regression and its support:

Column Meaning
LAMZ Positive terminal rate constant.
THALF ln(2)/LAMZ.
LAMZ_N Number of selected observations.
LAMZ_START, LAMZ_END Selected postdose time range.
LAMZ_SPAN Window span in estimated half-lives.
R2, R2ADJ Fit and adjusted fit statistics.

These fields summarize the chosen candidate. Use nca_lambda_z.csv for all candidates and nca_profiles.csv for the exact observations.

MRT fields

MRTLAST is AUMClast/AUClast. MRTINF_OBS and MRTINF_PRED use the corresponding infinite areas and apply route-specific corrections such as half the constant infusion duration. A modest change in lambda-z can affect MRT strongly because the infinite AUMC tail contains lambda-z squared in the denominator.

Route-dependent clearance and volume

Intravenous rows populate CL_OBS, CL_PRED, VZ_OBS, VZ_PRED, and, when valid, VSS_OBS/VSS_PRED. Extravascular rows instead populate CL_F_OBS, CL_F_PRED, VZ_F_OBS, and VZ_F_PRED. Blank IV fields on an oral row are correct schema behavior, not missing analysis.

Observed/predicted suffixes refer to which AUCinf/Clast tail convention was used. Vz depends on both clearance/AUC and lambda-z. Vss is an IV residence-time derivation and should not be expected for ordinary extravascular profiles.

Dependency review

When a derived field is blank, inspect upstream AUCinf, lambda-z, route, and quality action. When it is flagged but retained, preserve the flag with exported results. Never fill a blank volume by copying an apparent volume or a structural-model estimate.

Common mistakes

  • Reading R² instead of adjusted R² for automatic acceptance.
  • Removing /F from extravascular names.
  • Treating Vz and Vss as equivalent.
  • Retaining a derived number after rejecting its upstream AUCinf.

Checklist

  • Inspect window times, N, adjusted R², and span.
  • Match observed/predicted tail conventions.
  • Use route-appropriate clearance and volume fields.
  • Trace blanks and flags upstream.
  • Compare unrounded values during validation.

Further reading

See terminal controls, parameter-dependency theory, and AUMC/MRT/Vss theory.