Documentation

Chapter 32 — Exposure–response concepts and models

Exposure–response analysis relates individual drug exposure to efficacy, safety, biomarker, event, or longitudinal outcomes. It is central to dose justification and benefit–risk evaluation, but it is also easy to overinterpret: individual exposure is not randomised, model shape can be weakly identified, endpoint links change effect meaning, and a statistically significant association is not automatically a causal dose effect.

Continuous exposure–response model shapes

This chapter builds the scientific and statistical foundation for Chapter 33’s complete nlmx er command guide. It is written for readers new to E–R modelling while retaining the parameterisations, diagnostics, assumptions, and reporting boundaries needed by experienced pharmacometricians.

What you will learn

  • how to define exposure metrics, endpoint estimands, analysis populations, and clinically meaningful contrasts;
  • why randomised dose does not remove confounding from individual-exposure analyses;
  • how linear, log-linear, Emax, sigmoid Emax, and hockey-stick models behave and fail;
  • how logistic, proportional-odds, Poisson/quasi-Poisson/negative-binomial, Kaplan–Meier, log-rank, and Cox methods map to endpoint scales;
  • how censoring, ties, proportional hazards, repeated visits, placebo correction, covariates, and selection affect interpretation;
  • how to report differences, odds ratios, rate ratios, hazard ratios, uncertainty, bootstrap success, diagnostics, and causal limits.

Executed nlmx 4.16.0 evidence

Six known-truth analyses from data/er were executed and preserved under documents/ch32/results:

Endpoint family Analysis Main teaching result
continuous CHG versus AUC, five shapes Emax selected; EC50 below active range and imprecise
binary RESP/BOR versus AUC, 50-replicate bootstrap Emax selected; broad EC50 uncertainty; 49/50 Emax refits succeeded
ordinal AE grade versus Cmax linear cumulative-logit slope 0.331; IQR OR 2.55
count events versus AUC with follow-up offset Poisson slope −0.0245; NB size unbounded because no extra dispersion
time-to-event PFS versus AUC 52 events; log-rank p=0.001; IQR continuous HR 0.481
longitudinal score versus AUC over weeks placebo-corrected slope strengthened from −0.055 to −0.142

These runs demonstrate software behavior and interpretation. They are synthetic, small, and not evidence for a real compound. The 50-replicate binary bootstrap is a documentation smoke run, not a final uncertainty analysis.

Executed binary E–R analysis

A disciplined reasoning sequence

  1. State the clinical decision and estimand.
  2. Define exposure window, units, provenance, and uncertainty.
  3. Define endpoint, assessment time, population, intercurrent-event and missing/censoring rules.
  4. Draw the causal structure and prespecify adjustment.
  5. Choose a small scientifically credible model set and effect contrast.
  6. Examine data support, overlap, exclusions, events/categories/visits, and placebo.
  7. Fit, diagnose, quantify uncertainty, and test sensitivity.
  8. Translate to absolute clinical outcomes and state causal and transportability limits.

The chapter contains 24 numbered pages following the DOCUMENTATION.md budget. Use the model and estimand catalogue for formula lookup or continue with 32.1 Why perform exposure–response analysis.