Documentation

28.34 Concentration-time profile plots

Concentration-time profile plots

Profile figures display median and default 5th–95th percentile bands over the selected interval, plus a configurable number of faint individual profiles. --profile-scale linear|log|both chooses linear, semilog, or both outputs; --no-profile-plot suppresses the figure. Settings control exact profile percentiles and number of individuals.

Why this matters

This decision changes what population, random quantity, time interval, or numerical summary the command represents. For a novice, the safest habit is to write the question in one sentence before choosing an option, then verify that the resolved settings and output columns express that same question. For a reviewer, the important distinction is between what was assumed, what was randomly generated, what was calculated, and what can legitimately be concluded.

Detailed behavior

  • Linear scale emphasizes peaks and absolute differences; log scale reveals terminal behavior and low concentrations.
  • The plotted profiles correspond to the metric-profile machinery, not necessarily noisy simulated DV.
  • Individual lines provide distribution texture but should not obscure the band.
  • Use consistent axes when comparing dose arms or scenarios.

The subject-level table is the bridge between the design and the exposure result. Use it to check IDs, arms, population labels, age, sex, weight, dose, interval start, tau, ETA values, and added covariates. Use the metric table to check one row per subject and simulation, the requested metric columns, and COVERED. Use pooled and replicate summaries for different purposes: pooled rows describe all simulated subject outcomes, while replicate intervals describe how a finite simulated study result varies from study to study.

Example command or settings fragment

nlmx sims run.ctl --profile-scale both --plot-width 7 --plot-height 5 --plot-dpi 300

Start with a small smoke run and inspect the transcript before scaling. For command-line work, quote expressions containing comparison signs, brackets, or commas as required by the shell. For a permanent analysis, prefer a settings file: it exposes settings-only controls, resolves paths relative to itself, rejects unknown keys, and is echoed in fully resolved form with the output.

Interpretation and quality control

Read profiles with numerical CMAX, CTROUGH, AUC, and coverage tables. Log plots require positive values and can visually exaggerate clinically negligible low-concentration differences.

At minimum, reconcile the console summary with the CSV/JSON result, inspect warnings and notes, confirm subject and observation counts, verify requested groups and targets, and review the source model's applicability. A chart can reveal shape and subgroup patterns, but every reported number should come from the tables. If a result changes a decision, run a prespecified sensitivity for Monte Carlo stability, parameter uncertainty, population assumptions, and the metric-profile source.

Common mistakes

  • Using autoscaled axes for side-by-side comparisons
  • Inferring target attainment from a ribbon alone
  • Forgetting what profile source was drawn

Also avoid overwriting a completed evidence folder merely to change styling. Create a new scenario directory or preserve the prior checksums so analytical changes remain distinguishable from presentation changes.

What to retain and report

  • the nlmx version, complete issued command, submitted settings, and resolved _settings.sims;
  • CTL, selected EXT, optional COV or parameter table, and supplied dataset or population-generation assumptions;
  • seed, subproblems, thread count, ETA/EPS and parameter-uncertainty policy;
  • metric interval, tau, profile source, grid, integration rule, group definitions, and target limits;
  • numerical tables, JSON, HTML, figures, transcript, checksums, warnings, sensitivities, and scoped interpretation.