41.14 Case 4: three estimation methods, one answer
What you will learn
- Run the same model under FOCE-I, Laplace and SAEM and read the three summaries side by side.
- Know why OFVs from different estimation methods are not compared as a test.
- Interpret an unfinished SAEM run, and say what it does and does not support.
- Use agreement between methods as a robustness check.
Prerequisites: 41.13 and Chapter 19, SAEM and Chapter 18, estimation theory.
The question: does the answer depend on the estimation method?
The evidence: three Chapter 20 bundles for the same data and structure: oral_focei, oral_laplace (METHOD=1 LAPLACE) and oral_saem (run20_saem.ctl).
Why compare methods
FOCE-I and Laplace approximate the marginal likelihood by expanding around each subject's mode; SAEM does not approximate, it samples, and the objective function is then computed by importance sampling. When the model is well behaved and the data informative, all three should arrive at nearly the same place. When they do not, something is wrong with the model, the data, or the approximation, and the disagreement is the first sign.
The three summaries
| FOCE-I | Laplace | SAEM | |
|---|---|---|---|
| Termination | successful, gradient < 1e-3 | successful, gradient < 1e-3 | not completed: burn-in reached NBURN = 120 without passing the stationarity test; 80 accumulation iterations |
| Iterations | 17 (255 evaluations) | 19 (285) | 200 |
| OFV | −423.668 | −420.371 | −420.960 |
| CL | 3.838 | 3.785 | 3.781 |
| V | 42.62 | 42.64 | 42.98 |
| KA | 1.132 | 1.142 | 1.155 |
| proportional SD | 0.1507 | 0.1493 | 0.1504 |
| ω² CL | 0.0553 | 0.0550 | 0.0562 |
| ω² V | 0.0538 | 0.0535 | 0.0533 |
| Standard errors | sandwich | none | none |
Relative to FOCE-I, the Laplace and SAEM estimates differ by −1.4 % and −1.5 % in CL, +0.1 % and +0.9 % in V, +0.9 % and +2.0 % in KA, and by less than 2 % in every variance and in the residual SD. That is the figure above: every dot lies within about 2 % of the dashed line.
The OFVs are not a test
OFV rises from −423.67 (FOCE-I) to −420.37 (Laplace) and −420.96 (SAEM): differences of 3.3 and 2.7. It is tempting to read this as "FOCE-I fits better". It does not follow. The three OFVs are different approximations of the same likelihood; the differences between them are the differences between approximations, not evidence about the model. A likelihood-ratio test needs two models under the same approximation. Differences of a few units between methods on the same model are normal and carry no information about which model is right.
For SAEM, two lines in the summary make the point explicit:
SAEM: final SAEM objective -646.9183 (not a likelihood; the OFV is from importance sampling)
Importance sampling: 300 draws per subject (multivariate-t proposal at the conditional mode, antithetic);
effective sample size min 243, median 257
The −646.9 is SAEM's internal criterion and is not an OFV at all. The reported −420.96 comes from a separate step, importance sampling at the final estimates, with an effective sample size of 243 to 257 out of 300 draws per subject, which is a healthy fraction (81–86 %).
The unfinished SAEM run
SAEM's termination reads NOT COMPLETED. Its burn-in phase is meant to end when the parameter trajectories look stationary; here it ran its allotted 120 iterations without passing that test, then spent 80 iterations on accumulation anyway. What does that mean?
- It does not mean the answer is wrong. The estimates lie within 2 % of the FOCE-I values, which converged by a different route.
- It does mean the run did not demonstrate its own convergence. One cannot cite SAEM as a second converged run; one can cite it as a consistent run.
- The remedy is more iterations, not different data: raise the burn-in budget and re-run. The 200 iterations used are very few (the run took 0.6 s), and the point of a robust SAEM run is a long burn-in.
The ranking of evidence
| Evidence | Strength |
|---|---|
| FOCE-I converged, SEs available, κ 24 | primary result |
| Laplace converged, within 1.4 % | second approximation agrees |
| SAEM within 2 % but not completed | consistent, not confirmatory |
The estimates are not sensitive to the method on this data. A conclusion that held under all three would be one that does not depend on the approximation.
The decision
| Question | Evidence | Decision | Reversible? |
|---|---|---|---|
| Which method reports the model? | FOCE-I converged with SEs; others agree within 2 % | FOCE-I; cite Laplace as agreeing and SAEM as consistent | yes |
| Do the methods disagree materially? | all parameters within 2 % | No | yes |
| What to do about SAEM? | burn-in did not pass | Re-run with a longer burn-in if SAEM is to be cited as a converged check | yes |
What this case does not show
This is a well-behaved model with 24 subjects. On sparse data, high shrinkage or strongly non-linear models, FOCE-I and SAEM can disagree by much more, and the disagreement is the finding. Here, they agree because the problem is easy; that is information about the problem, not about the methods.
Review checklist
- Did you compare estimates, not OFVs, across methods?
- Is an unfinished run cited as consistent rather than confirmed?
- Do you know what the importance-sampling effective sample size is for the SAEM OFV?
- Did you write down why one method was chosen as primary?
Navigation
See the previous page, the next page and the complete case-study reference.