32.5 Continuous endpoints: the linear model
The linear model is E(Y|C)=E0+βC plus covariates. E0 is expected response at zero exposure for the reference subject, and β is a constant change per exposure unit. It is transparent and often a useful benchmark, but it assumes no curvature and extrapolates without bound.
Core concepts
- Interpret β with units: response units per exposure unit. A clinically useful contrast multiplies β by an IQR, SD, doubling-equivalent, or prespecified change.
- Residual diagnostics assess constant variance, linearity, influential points, and normal-error adequacy.
- When placebo exists at C=0, E0 is anchored; without low exposure, the intercept may be extrapolated.
Keep five layers separate: the dose assignment, the individual exposure, the endpoint definition, the statistical estimand, and the clinical decision. A fitted curve connects exposure and endpoint within the analysed data; it does not automatically identify the effect of changing dose or exposure in another population.
Worked interpretation
If β=−0.15 score units per AUC unit, moving AUC from 27 to 50 predicts about −3.45 score units, conditional on the model and covariates.
Calculation and interpretation
For two exposures C1 and C2, the model-based mean contrast is β(C2−C1). Suppose β = −0.15 score units per AUC unit, C1 = 27, and C2 = 50. The contrast is −0.15 × 23 = −3.45 score units. Its sign is beneficial only if lower scores are better. The intercept E0 is the predicted mean at zero exposure for reference covariates; it is not automatically the observed placebo mean after adjustment.
The slope is constant everywhere: an increase from 10 to 20 has the same predicted effect as 60 to 70. Check this assumption with a smooth trend, residual-versus-exposure plot, and binned observed summaries. Fan-shaped residuals suggest nonconstant variance; curved residuals suggest misspecified shape; a single remote exposure can dominate the slope.
Scale the reported effect to something readers can understand—an IQR, SD, or clinically plausible dose-induced exposure shift. Show predictions and intervals at the actual exposure values. Do not extend the line to negative exposure or far beyond the observed maximum, because an unbounded linear equation can imply impossible endpoint values.
For a novice, translate every coefficient back to the endpoint scale. Name the starting exposure, ending exposure, predicted outcome at both, contrast, interval, and observed support. For categorical or survival endpoints, also show absolute probabilities or survival estimates because odds and hazard ratios can be hard to interpret clinically.
Quality control and scientific review
Plot observed data and binned summaries, inspect residuals and leverage, and restrict interpretation to supported exposure.
Review sample size alone only after checking events, category cells, visit counts, placebo support, exposure overlap, exclusions, and missingness. A statistically precise curve can still be clinically irrelevant, confounded, extrapolated, or based on an endpoint definition that does not match the intended estimand.
Common mistakes
- Reporting a one-unit slope when one unit is clinically tiny
- Extrapolating a safety slope far above observed exposure
- Treating a significant exposure term as proof that the selected shape or causal story is correct
Evidence to retain
- exposure definition, window, units, derivation, estimation uncertainty, and distribution by arm;
- endpoint derivation, time origin/visit, analysis population, missing/censoring rules, and exclusions;
- candidate models, covariate rationale, contrasts, selection criterion, diagnostics, failed/unstable fits;
- effect estimates with intervals, observed range, sensitivity analyses, software version, settings, and checksums.
Navigation
See the previous page, next page, and model and estimand catalogue.