Documentation

24.42 Posterior-analysis reporting template

Use the following structure so another pharmacometrician can reproduce and review the analysis.

1. Objective and scope

State the clinical/model-development question, base run, target parameters/ETAs, covariates, forms, references, statuses, proxy groups, primary method, and sensitivity analyses.

2. Posterior construction

Report PHI/ETC/reconstruction counts, approximation, mode settings, covariance repair rule, failed-subject policy, point-EBE status, moment identity, shrinkage, and weak-subject counts. Explain source differences by study or population.

3. Perturbation schedule

Report response, draw method, posterior draws, resampling method/fraction/replicates/strata, base-parameter draws, seed, threads, scheduled fits, checkpoints, and failure limit.

4. Features and learners

Document standardization, zero-variance drops, correlation threshold/clusters, time-varying summary, feature count, target ETA mapping, learners, primary learner, CV folds, hyperparameter grids, and selection rules.

5. Stability and error control

Report configured and effective probability thresholds, uncertainty lower bound, sign/form/agreement gates, variance consistency, PFER/FDR mode, bound/target, average selected set size, calibration replicates, and probability intervals.

6. Results

For every pair show chosen form, equation and pair probabilities, interval, learner probabilities, sign/form stability, agreement, cluster, coefficient median/quantiles, IIV explained, classification, and reason. Include failures and uncertain/rejected clinically important hypotheses.

7. Final model and interpretation

State whether joint refit ran, its OFV/convergence/covariance/coefficients, diagnostics, clinical effect/exposure interpretation, frozen/SCM comparison, sensitivity conclusions, limitations, and required external confirmation.

8. Reproducibility

Provide nlmx version, complete command, input and normalized configuration, input manifest, checksums, run times, output location, reviewer, and approval date.

Common mistakes

  • Reporting only retained rows.
  • Omitting posterior and failure diagnostics.
  • Presenting two-stage coefficients as final estimates.
  • Hiding loose PFER bounds or sensitivity disagreements.
  • Separating the report from its machine-readable bundle.

Checklist

  • Complete every section or state why it is not applicable.
  • Link figures to source tables.
  • Use consistent units, references, and terminology.
  • Preserve reviewer decisions and unresolved limitations.

Further reading

Use the primary generated report as a machine-produced companion, not a replacement for scientific interpretation.