20.5 Supported ADVANs and TRANS parameterizations
Analytic support includes ADVAN1–4, 11 and 12 with documented TRANS combinations: TRANS1–2 for ADVAN1/2; TRANS1/3/4/5/6 for ADVAN3/4; TRANS1/4/6 for ADVAN11/12. ADVAN10 uses Michaelis–Menten elimination solved as an ODE. ADVAN5/7 support general linear models from rate constants.
The same clinical structure can use different parameterizations. Clearance/volume and micro-rate constants generate equivalent predictions only when mappings, scaling and compartments match. Parameter bounds and covariance interpretation differ.
Fixed-parameter prediction comparison is the first validation step. Test bolus, infusion, oral, repeated dosing and observation compartments relevant to the study. Analytic solutions should agree with independent reference simulation at declared tolerance.
Unsupported combinations must fail clearly, not silently approximate. Version scope matters; rerun validation after upgrades.
Choosing an ADVAN deliberately
Use an analytic ADVAN when it exactly represents the intended linear disposition model; it is usually faster and removes ODE-solver tolerance as a source of variation. Use $DES when the dynamics require custom differential equations, nonlinear processes, time-varying mechanisms or structures not represented by an analytic routine. $PRED is appropriate for direct prediction or general likelihood logic, but the analyst must then implement more behavior explicitly.
TRANS controls how named micro- or macro-parameters map into the solver. Two streams may describe the same compartments yet parameterize them differently. Confirm which quantities are clearance, volume, rate constant, intercompartmental clearance or steady-state volume, and confirm their units. When reproducing another software result, match the reference parameterization before attempting algebraic simplification.
Build a small structural qualification case with fixed parameters and no random effects. Compare predictions at strategically chosen times—including near dose time and late elimination—against hand calculations or a trusted reference. This separates structural translation from estimation behavior.
Common mistakes
Do not infer supported TRANS from ADVAN alone, compare parameters without transformation, or assume analytic and $DES implementations have identical event defaults. Avoid validating only a single-dose typical subject.
Checklist
- Confirm exact ADVAN/TRANS pair.
- Map parameters and scaling.
- Test all route/event patterns.
- Compare fixed predictions with reference.
- Record version and tolerances.
Further reading
Continue to ODE models, events, and Chapter 40’s planned compatibility matrix.