32.6 Continuous endpoints: the log-linear model

The log-linear model is E0+β ln(C) or E0+β ln(C+offset). It creates a steep low-exposure change that flattens as exposure rises. A multiplicative exposure change has a constant effect: doubling changes the mean by β ln 2.
Core concepts
- Log exposure is undefined at zero. Excluding placebo changes the fitted population and makes AIC incomparable with models using placebo.
- An offset retains placebo but changes the curve and must be justified; the default is half the smallest positive exposure when requested.
- Low positive exposures have high leverage because log changes rapidly near zero.
Keep five layers separate: the dose assignment, the individual exposure, the endpoint definition, the statistical estimand, and the clinical decision. A fitted curve connects exposure and endpoint within the analysed data; it does not automatically identify the effect of changing dose or exposure in another population.
Worked interpretation
In the executed continuous run, log-linear excluded 33 placebo subjects and was reported but not ranked because it used 65 rather than 98 subjects.
What the logarithm changes
With μ(C)=E0+β ln(C), multiplying exposure by r changes the mean by β ln(r). A doubling therefore changes it by 0.693β, regardless of starting positive exposure. This model has diminishing change per absolute exposure unit, but it has no finite plateau: response continues changing as exposure grows.
Placebo creates a structural problem because ln(0) is undefined. Excluding zero-exposure subjects estimates an active-only relationship and removes the placebo anchor. Adding an offset estimates a different curve: ln(C+a). If a is half the smallest positive exposure, the answer can depend materially on that one observation. Present offset sensitivity and never compare AIC with a model fitted to a different subject set.
Plot the x-axis on both original and logarithmic scales. Inspect the smallest positive values because they have high leverage after transformation. Record the base of the logarithm—nlmx uses the natural logarithm—and translate coefficients into a doubling or other multiplicative contrast rather than “per log unit,” which is rarely intuitive.
For a novice, translate every coefficient back to the endpoint scale. Name the starting exposure, ending exposure, predicted outcome at both, contrast, interval, and observed support. For categorical or survival endpoints, also show absolute probabilities or survival estimates because odds and hazard ratios can be hard to interpret clinically.
Quality control and scientific review
State zero handling, offset, included n, and whether fit criteria compare identical observations.
Review sample size alone only after checking events, category cells, visit counts, placebo support, exposure overlap, exclusions, and missingness. A statistically precise curve can still be clinically irrelevant, confounded, extrapolated, or based on an endpoint definition that does not match the intended estimand.
Common mistakes
- Comparing AIC across different subject sets
- Calling log-linear a saturating mechanism with an actual plateau
- Treating a significant exposure term as proof that the selected shape or causal story is correct
Evidence to retain
- exposure definition, window, units, derivation, estimation uncertainty, and distribution by arm;
- endpoint derivation, time origin/visit, analysis population, missing/censoring rules, and exclusions;
- candidate models, covariate rationale, contrasts, selection criterion, diagnostics, failed/unstable fits;
- effect estimates with intervals, observed range, sensitivity analyses, software version, settings, and checksums.
Navigation
See the previous page, next page, and model and estimand catalogue.