16.9 The individual NLS method

NLS fits a one-compartment model separately to each subject using the subject's complete doses, infusions, steady state, and sampling schedule. This is a standard two-stage starting-value approach, not a population likelihood fit.

Fitting mechanics

Levenberg–Marquardt optimizes log parameters so CL, V, and KA remain positive. Residuals are on the log concentration scale, corresponding to proportional error. For oral subjects, three KA starting values are tried and the best fit is retained. Infusion and repeated-dose predictions use the full event history.

Individual fits contribute typical values through log-scale aggregation and variability through the spread of individual estimates. Failed subjects are omitted from that method, not assigned zero.

Sparse fallback

When fewer than half of subjects can be fitted individually, a naive pooled fit of all subjects supplies typical values. This is a pragmatic starting-value fallback. It does not model inter-individual variability correctly and should not be reported as a final population analysis.

Flip-flop symmetry

In a one-compartment oral model, KA and the disposition rate CL/V can exchange roles without changing the concentration curve. Without IV evidence, autoinit reports the conventional solution KA > CL/V. Mechanistic identification still requires appropriate design or external knowledge.

Residual error

The median individual residual SD informs proportional error, constrained to 0.03–1; if no individual fit succeeds, 0.2 is used. This is a stable initial value, not a validated residual model.

Common mistakes

  • Calling two-stage NLS a population mixed-effects estimate.
  • Interpreting the pooled fallback's uncertainty as valid IIV.
  • Assuming KA is mechanistically identified from oral data alone.
  • Treating the 0.03 residual floor as observed assay precision.

Checklist

  • Count successful individual fits.
  • Review full regimen simulation assumptions.
  • Inspect CL/V/KA distributions and outliers.
  • Identify pooled fallback use.
  • Reevaluate residual structure during population fitting.