28.21 ETA, EPS, and variance scaling
--sim-etas sample|zero controls between-subject random effects; --sim-eps sample|zero controls residual errors at observation records. --omega-scale and --sigma-scale multiply covariance elements, not standard deviations. A scale of 0 removes the corresponding variance; 0.25 halves the standard deviation because SD is the square root of variance.
Why this matters
This decision changes what population, random quantity, time interval, or numerical summary the command represents. For a novice, the safest habit is to write the question in one sentence before choosing an option, then verify that the resolved settings and output columns express that same question. For a reviewer, the important distinction is between what was assumed, what was randomly generated, what was calculated, and what can legitimately be concluded.
Detailed behavior
- Dense metric profiles use the subject ETA but no residual error.
- Sampled or observed metric profiles can include EPS depending on the source and
sim-epspolicy. - Typical-subject runs with ETAs zero answer a different question from population exposure distributions.
- Variance scaling is a scenario analysis, not re-estimation of variability.
The subject-level table is the bridge between the design and the exposure result. Use it to check IDs, arms, population labels, age, sex, weight, dose, interval start, tau, ETA values, and added covariates. Use the metric table to check one row per subject and simulation, the requested metric columns, and COVERED. Use pooled and replicate summaries for different purposes: pooled rows describe all simulated subject outcomes, while replicate intervals describe how a finite simulated study result varies from study to study.
Example command or settings fragment
nlmx sims run.ctl --sim-etas zero --sim-eps zero --omega-scale 0 --sigma-scale 0 --grid-points 481
Start with a small smoke run and inspect the transcript before scaling. For command-line work, quote expressions containing comparison signs, brackets, or commas as required by the shell. For a permanent analysis, prefer a settings file: it exposes settings-only controls, resolves paths relative to itself, rejects unknown keys, and is echoed in fully resolved form with the output.
Interpretation and quality control
Label the estimand precisely: typical individual prediction, individual exposure distribution, assay/noise sensitivity, or combined observed-data variability. Never compare scaled and unscaled target attainment without naming the changed variance component.
At minimum, reconcile the console summary with the CSV/JSON result, inspect warnings and notes, confirm subject and observation counts, verify requested groups and targets, and review the source model's applicability. A chart can reveal shape and subgroup patterns, but every reported number should come from the tables. If a result changes a decision, run a prespecified sensitivity for Monte Carlo stability, parameter uncertainty, population assumptions, and the metric-profile source.
Common mistakes
- Treating variance scale as SD scale
- Expecting EPS to alter dense CAVG
- Calling ETA-zero results population predictions
Also avoid overwriting a completed evidence folder merely to change styling. Create a new scenario directory or preserve the prior checksums so analytical changes remain distinguishable from presentation changes.
What to retain and report
- the nlmx version, complete issued command, submitted settings, and resolved
_settings.sims; - CTL, selected EXT, optional COV or parameter table, and supplied dataset or population-generation assumptions;
- seed, subproblems, thread count, ETA/EPS and parameter-uncertainty policy;
- metric interval, tau, profile source, grid, integration rule, group definitions, and target limits;
- numerical tables, JSON, HTML, figures, transcript, checksums, warnings, sensitivities, and scoped interpretation.
Navigation