14.11 Tmax exclusion, manual windows, and regression weighting
Automatic terminal-slope selection begins with the observations after the profile's observed Tmax. By default, the Tmax observation itself is excluded. That convention helps prevent an absorption or distribution point from entering a line intended to describe terminal decline. It is a useful guardrail, not proof that every later point belongs to the terminal phase.
nlmx also supports controlled departures from the automatic choice. A terminal region can be specified by a time range, a starting or ending time, or a requested number of last eligible observations. Profile-specific overrides and exclusions allow an analyst to document why a particular point or window was accepted. These choices should be made from a protocol or a review rule, not selected repeatedly until a preferred half-life appears.
Weighting choices
The regression model is always linear in log concentration:
ln(Ci) = intercept − lambda_z × ti + error_i
The available weighting conventions are uniform, 1/y, and 1/y², where y is the observed concentration. Uniform weighting is the default. Weighting changes how strongly observations at different concentrations influence the fitted line; it does not turn the terminal regression into a population or mechanistic model. A weighted estimate should therefore be accompanied by the selected rule and a sensitivity comparison when it materially affects conclusions.
Manual selections still require a declining line and enough usable, positive observations. They may be retained even when the adjusted R² is below the automatic threshold, but the low-fit condition is flagged. This distinction is important: a manual choice records analyst judgment; it does not erase numerical evidence that the line is uncertain.
Review workflow
First inspect the concentration-time profile on linear and semilog scales. Then review all candidate windows, the automatic winner, exclusions, and any manual override. Finally compare lambda_z, span, adjusted R², extrapolated area, and downstream parameters. A defensible record explains both the biological rationale and the numerical consequence.
Common mistakes
- Including Tmax simply because it makes adjusted R² larger.
- Treating
1/y²weighting as automatically more accurate. - Using a manual window without recording its rationale.
- Assuming a manual selection bypasses all quality diagnostics.
Checklist
- Confirm whether Tmax is included or excluded.
- Record the window and weighting rule exactly.
- Inspect excluded points and all eligible candidates.
- Compare the manual and automatic results.
- Preserve warnings and rationale in the analysis record.
Further reading
Continue with terminal span and diagnostic flags, or return to best-fit selection.