Documentation

28.28 FLUCT, SWING, PTR, and CLSS

FLUCT, SWING, PTR, and CLSS

FLUCT is 100(CMAX-CMIN)/CAVG, SWING is (CMAX-CMIN)/CMIN, PTR is CMAX/CMIN, and CLSS is Dose/AUCTAU. These metrics are algebraically derived from the selected profile, so their reliability inherits peak, trough, AUC, interval, and coverage decisions.

Why this matters

This decision changes what population, random quantity, time interval, or numerical summary the command represents. For a novice, the safest habit is to write the question in one sentence before choosing an option, then verify that the resolved settings and output columns express that same question. For a reviewer, the important distinction is between what was assumed, what was randomly generated, what was calculated, and what can legitimately be concluded.

Detailed behavior

  • SWING and PTR become unstable when CMIN approaches zero.
  • CLSS is apparent clearance for extravascular dosing and depends on bioavailability assumptions.
  • Dose must be the administered interval dose in consistent units.
  • Percent fluctuation and dimensionless ratios should not be summarised geometrically when zeros or invalid values occur.

The subject-level table is the bridge between the design and the exposure result. Use it to check IDs, arms, population labels, age, sex, weight, dose, interval start, tau, ETA values, and added covariates. Use the metric table to check one row per subject and simulation, the requested metric columns, and COVERED. Use pooled and replicate summaries for different purposes: pooled rows describe all simulated subject outcomes, while replicate intervals describe how a finite simulated study result varies from study to study.

Example command or settings fragment

nlmx sims run.ctl --metrics CMAX,CMIN,CAVG,AUCTAU,FLUCT,SWING,PTR,CLSS

Start with a small smoke run and inspect the transcript before scaling. For command-line work, quote expressions containing comparison signs, brackets, or commas as required by the shell. For a permanent analysis, prefer a settings file: it exposes settings-only controls, resolves paths relative to itself, rejects unknown keys, and is echoed in fully resolved form with the output.

Interpretation and quality control

Inspect numerator and denominator metrics before interpreting a ratio. Report extreme ratios with robust quantiles and identify whether they arise from scientifically plausible low troughs or numerical/profile limitations.

At minimum, reconcile the console summary with the CSV/JSON result, inspect warnings and notes, confirm subject and observation counts, verify requested groups and targets, and review the source model's applicability. A chart can reveal shape and subgroup patterns, but every reported number should come from the tables. If a result changes a decision, run a prespecified sensitivity for Monte Carlo stability, parameter uncertainty, population assumptions, and the metric-profile source.

Common mistakes

  • Calling CLSS absolute clearance after oral dosing
  • Ignoring near-zero CMIN
  • Reporting ratios without component metrics

Also avoid overwriting a completed evidence folder merely to change styling. Create a new scenario directory or preserve the prior checksums so analytical changes remain distinguishable from presentation changes.

What to retain and report

  • the nlmx version, complete issued command, submitted settings, and resolved _settings.sims;
  • CTL, selected EXT, optional COV or parameter table, and supplied dataset or population-generation assumptions;
  • seed, subproblems, thread count, ETA/EPS and parameter-uncertainty policy;
  • metric interval, tau, profile source, grid, integration rule, group definitions, and target limits;
  • numerical tables, JSON, HTML, figures, transcript, checksums, warnings, sensitivities, and scoped interpretation.

See the previous page, next page, and complete sims command and settings index.