Documentation

How steady-state simulation is computed

nlmx applies a steady-state dose and evaluates the fitted model over one complete dosing interval. The default grid contains 240 subintervals and 241 predictions. Analytic ADVANs, differential-equation models, lag time, and infusions use the model's own mechanics.

The prediction grid supplies maximum, minimum, end-of-interval trough, trapezoidal AUC, and average concentration. Grid resolution is part of the numerical method: narrow peaks or complex infusions may need convergence checks through settings even though no CLI grid switch is exposed.

Verify dose event, compartment, interval, infusion/route, units, steady-state interpretation, and model handling of covariates/ETAs. A numerically smooth curve is not evidence that the clinical regimen was encoded correctly.

How steady-state simulation is computed

Common mistakes

  • Treating a forest ratio or reference-band class as covariate-selection evidence, causality, or an automatic dosing recommendation.
  • Omitting the reference subject, uncertainty source, regimen, subgroup denominator, data support, or fitted-model diagnostics.
  • Confusing parameter-uncertainty intervals, BSV ranges, and subject-bootstrap intervals because they share one graphic.

Page checklist

  • The numerator, denominator, fitted model, covariate settings, and units are explicit.
  • The interval source and clinical meaning are distinguished from BSV and selection uncertainty.
  • Tables, resolved settings, commands, diagnostics, limitations, and confirmation evidence are retained.

Further reading