Documentation

41.28 Case 7: dose levels against an exposure window

Three dose levels against an exposure window

What you will learn

  • Read a sims run as a question about a population, not about one subject.
  • Turn an exposure window into a range of clearances, and use that range to predict the answer before reading the table.
  • Compare three dose levels on two targets at once and say why one dose wins.
  • Tell sampling variation between arms from a real dose effect.

Prerequisites: Chapter 28, simulating a study and the covariate model of Case 5 (41.24).

The question: an adult dose of 100 mg once daily is proposed. How many adults would have an average concentration between 0.6 and 1.4 mg/L, and does the answer change at half or twice the dose?

The evidence: two Chapter 28 bundles, adult_fixed (one dose) and dose_levels (three doses). Both simulate the final covariate model of Case 5 (the qualified model of Chapter 26, with its estimates read from the .ext file); neither fits anything.

What the program does

nlmx sims never estimates. It reads a control stream and a set of final estimates, generates a data set of simulated subjects (covariates, doses, sampling times), simulates concentrations from the model with random effects drawn for each subject, then computes exposure metrics from each subject's concentration–time curve and summarises them. The whole run is repeated --subproblems times, so that the result carries its own Monte Carlo spread.

The first bundle is the whole recipe in one command line:

nlmx sims run28.ctl --ext run26.ext --estimates final \
  --subjects 48 --subproblems 20 --seed 28001 \
  --population adult --adult-age 18-80 --adult-age-mean 45 --adult-age-sd 15 \
  --adult-weight-mean 70 --adult-weight-cv 15% \
  --sex-sampling balanced --covariate "EGFR=normal(95,20)[30,160]" \
  --dose 100 --tau 24 --steady-state yes \
  --metrics CMAX,TMAX,CMIN,TMIN,CTROUGH,CAVG,AUCTAU,FLUCT,SWING,PTR,CLSS \
  --targets "CAVG:0.6-1.4,CMAX:<=5" --summary-by SEX

Read it as a protocol. Who: 48 adults per simulation aged 18–80 (mean 45, SD 15), weight centred at 70 kg with a 15 % coefficient of variation, half women, with an eGFR drawn from a normal distribution with mean 95 and SD 20 and truncated to 30–160. What: 100 mg every 24 h, at steady state. How many times: 20 simulations, hence 20 × 48 = 960 simulated subjects. Judged against: the average concentration over the dosing interval (CAVG) inside 0.6–1.4 mg/L, and the peak (Cmax) at or below 5 mg/L.

One dose: adult_fixed

Metric Mean Reading
Cmax 2.203 peak, mg/L
CAVG 1.07 average over 24 h
AUC over the interval 25.69 mg·h/L
CL at steady state 4.241 L/h

Two of these numbers constrain each other, and the constraint is the first thing to check. At steady state with complete absorption, the area under the curve over one interval equals the dose divided by clearance, and the average concentration is that area divided by the interval:

\[\text{AUC}_\tau = \frac{\text{Dose}}{\text{CL}}, \qquad C_{avg} = \frac{\text{AUC}_\tau}{\tau} = \frac{\text{Dose}}{\text{CL}\cdot\tau}.\]

The table is consistent with it: 25.69 ÷ 24 = 1.070, which is the reported mean CAVG. (A mean of ratios is not the ratio of means, so 100 ÷ 4.241 = 23.6 is close to, but not the same as, the 25.69 that is the mean of 100 ÷ CL over subjects; the mean of 1/CL is larger than the reciprocal of the mean CL.)

The targets are counted subject by subject:

Target Subjects inside Percent Across the 20 simulations
CAVG 0.6–1.4 793 of 960 82.6 73.91–90.68
Cmax ≤ 5 959 of 960 99.9 98.91–100

The right-hand column is the program's own measure of Monte Carlo noise: in the worst of 20 simulations of 48 subjects, 73.9 % were inside the window; in the best, 90.7 %. A single small simulation would have said anything between those. The pooled count, 793 of 960, has a binomial 95 % interval of about 80.1–84.9 % (treating the 960 subjects as independent draws, which they are, because each is simulated afresh).

Three doses: dose_levels

The second bundle changes one thing, the dose: --dose-levels 50,100,200 makes three arms of 20 subjects, repeated 15 times, so 300 subjects per arm and 900 in all.

Arm Mean CAVG Mean AUC Mean CL CAVG 0.6–1.4 Cmax ≤ 5
50 mg 0.500 12.00 4.463 19.67 % (59 of 300) 100 %
100 mg 0.941 22.58 4.742 89.33 % (268 of 300) 100 %
200 mg 2.028 48.67 4.392 8.667 % (26 of 300) 90 % (270 of 300)
All arms 39.22 % (353 of 900) 96.67 % (870 of 900)

The pooled row is the trap of this table. 39.22 % is an average over three arms that have nothing in common, and no reader should use it: a target that is met by one arm and missed by the others has no meaningful pooled value. The by-arm rows are the result.

Predicting the table before reading it

The window can be turned into a window on clearance, which the model describes directly. Since CAVG = Dose/(CL·τ), a subject is inside 0.6–1.4 mg/L when

\[\frac{\text{Dose}}{24\times 1.4} \;\le\; \text{CL} \;\le\; \frac{\text{Dose}}{24\times 0.6}.\]

For 100 mg that is 2.976 ≤ CL ≤ 6.944 L/h. The 100 mg arm's own clearance distribution runs from a 5th percentile of 2.949 to a 95th percentile of 6.944. The window therefore covers almost exactly the middle 90 % of the clearance distribution, and the observed 89.33 % is what that says it should be. The 200 mg arm needs 5.95 ≤ CL ≤ 13.9, and only subjects above 5.95 L/h are in range: with a mean clearance of 4.39 and an SD of 1.17, that is about 1.3 SD above the mean, or roughly 9 % of the arm; the table has 8.667 %. For 50 mg the window is 1.49–3.47 L/h and the lower part of the clearance distribution is in range, about one subject in five; the table has 19.67 %.

This is the habit the page is meant to teach: before reading a simulated attainment table, translate the target into the quantity the model controls, and see whether the table is the area under the right part of its distribution. A table that fails this check has a setting problem, not a pharmacology result.

The peak concentration is a different question

At 200 mg the peak constraint starts to bind: the 95th percentile of Cmax is 5.339 mg/L, and 10 % of subjects are above 5. The two targets fail for different reasons. At 200 mg the average is wrong for nearly everyone (it is about twice the upper limit), while the peak is wrong for one subject in ten. A dose that missed only the peak target might be rescued by splitting it into two administrations; one that misses the average cannot. The two targets answer different questions about the regimen, and both belong in the decision.

Sampling variation between arms

The arms are not a controlled experiment of the dose. Each arm draws its own subjects, so the mean clearances above differ (4.46, 4.74, 4.39): the 100 mg arm happens to have subjects with a higher clearance, and its mean AUC (22.58) is therefore less than twice the 50 mg arm's (12.00), where a pure dose effect would give 24. Dividing AUC by dose removes the dose and leaves 1/CL, which is the thing that differs. Three consequences follow.

  1. Do not compute dose proportionality from the arm means of a simulation. It is exact in the model (the model is linear in dose) and noisy in the output.
  2. The arm-level attainment is noisy too. The program reports 78.5–100 % across the 15 simulations for the 100 mg arm: individual simulations of 20 subjects are far too small to decide anything.
  3. The between-arm differences in attainment are not noise. 89 %, 20 % and 9 % differ by much more than any of the ranges overlap.

Reading the two bundles together

The two bundles used different seeds, subject counts and (for the first) different demographic settings, so their 100 mg results are not interchangeable: 82.6 % in adult_fixed and 89.3 % in dose_levels. They are two different virtual populations, and both are valid answers to different questions. A report quotes the one whose population matches the intended patients, with its settings. The difference is, at the same time, the right size of caution about a single attainment percentage: a 7-point difference arose from a change of population and of random numbers alone.

The decision

Question Evidence Decision Reversible?
Does 100 mg meet the average-exposure target? 89.33 % of 300 (arm), 82.6 % of 960 (fixed population) yes, as the candidate adult dose; about 83–89 % of adults in range yes
Does 200 mg? 8.667 %; Cmax ≤ 5 held for 90 % no yes
Does 50 mg? 19.67 % no yes
Can the pooled 39.22 % be quoted? it averages three unlike arms no yes

Would a different decision follow? If the target were set by the peak rather than the average, 200 mg would still fail (90 % against a 95 % aim); if the window were widened to 0.4–2.0 mg/L, 50 mg and 200 mg would change, and the clearance translation above would show by how much before any run.

What this case does not show

Both runs assume the model: the typical clearance and its covariate effects are the estimates of Case 5, so the simulation inherits all of that model's uncertainty (page 41.30 adds it). The populations are generated, not observed, and the weight, age and eGFR distributions are the analyst's choice. A target attainment percentage is a statement about the virtual population, not about a particular patient.

Review checklist

  • Can you convert the exposure window into a window on clearance, and say what fraction of the clearance distribution it covers?
  • Do you refuse to quote a pooled attainment across arms that were chosen to differ?
  • Have you separated the Monte Carlo range across simulations from the difference between arms?
  • Is the population of the run, not only the dose, stated next to every attainment figure?

See the previous page, the next page and the complete case-study reference.