Documentation

27.27 Fixed-estimate versus parameter-uncertainty VPC

The default fixes THETA, OMEGA, and SIGMA at their estimates, so bands reflect simulated IIV, residual variability, design size, and Monte Carlo variation. --param-uncertainty draws a new parameter state per replicate and adds estimation uncertainty, often widening bands for small or imprecise datasets.

Fixed-estimate versus parameter-uncertainty VPC

Novice translation

This topic changes three practical decisions in a predictive-check review. First, neither choice is universally correct; they answer conditional versus uncertainty-integrated predictive questions. Second, parameter uncertainty should be based on a qualified COV or defensible empirical parameter sample. Third, report the policy prominently because visually similar figures can have different statistical interpretations. Keep those decisions separate: one defines what is simulated or summarised, another controls how evidence is displayed, and the last controls what conclusion the evidence can support. A reviewer should be able to reproduce each decision from the resolved settings and numerical tables, not infer it from the appearance of the figure.

What to understand

  • Neither choice is universally correct; they answer conditional versus uncertainty-integrated predictive questions.
  • Parameter uncertainty should be based on a qualified COV or defensible empirical parameter sample.
  • Report the policy prominently because visually similar figures can have different statistical interpretations.

Practical interpretation

Run fixed and uncertainty-inclusive sensitivities when estimation uncertainty could alter the decision.

Evidence to retain

For fixed-estimate versus parameter-uncertainty vpc, retain the issued command, vpc_settings.vpc, the source model/data/result identifiers, seed and replicate count, the relevant CSV/JSON fields, warnings and notes, and the exact figure used for interpretation. Record any sensitivity run that changed the conclusion. If an option was selected after seeing the data, label that analysis exploratory. This evidence separates a reproducible diagnostic decision from a visual impression and lets another pharmacometrician check counts, transformations, exclusions, and uncertainty assumptions.

Common mistakes

  • Calling default bands unconditional
  • Using a failed covariance matrix
  • Comparing widths without stating policy

Page checklist

  • Define uncertainty target
  • Qualify source
  • Compare sensitivity
  • Label figure/report

Further reading