Documentation

31.8 Sample sizes and bracketing the crossing

Sample sizes and bracketing the crossing

--sample-sizes accepts comma/space/semicolon-separated positive whole numbers. Values are sorted and deduplicated. With no list, the template subject count becomes the single N.

What the controls mean

  • Use at least three useful sizes around the expected crossing for SSE interpolation.
  • FIM scales continuous information and rounds upward; SSE interpolates observed point estimates.
  • A coarse or noisy grid can yield a misleading crossing or only “not reached”.

The issued command is only the beginning of the audit trail. Always distinguish the reference model, the design template, the resolved scenario, the replicate-specific truth, the fitted result, and the test decision. A value can be correct at one layer and misinterpreted at another.

Command or settings pattern

--sample-sizes 30,45,60

Command-line values override settings-file values. Use a fresh folder for an analytical run; preserve the command, resolved settings, log, checksums, and row-level data. Defaults are versioned behavior, so a production protocol should state important values explicitly.

Interpretation and quality control

Plot intervals, confirm a broadly monotone trend, add points near the threshold, and implement feasible arm counts after rounding.

For a novice review, first confirm counts and labels, then inspect numerical values, then ask whether the assumptions represent the proposed clinical study. For an expert review, additionally reconcile aggregates from row-level output, reproduce a subset of trials, and compare the implementation with an independent reference where the claim requires it.

Common mistakes

  • Supplying fractional or zero subjects
  • Calling the smallest tested passing N the exact minimum
  • Reporting a point estimate without its denominator, interval, method, and version

Minimum evidence to retain

  • nlmx version, command, .power file, resolved settings, seed, threads, and output checksums;
  • control stream, design dataset, EXT/COV or parameter sets, and their provenance;
  • scenario table, replicate rows and failures, method summaries, plots, report, and interpretation;
  • prespecified criteria, Monte Carlo target, validation scope, deviations, and reviewer decisions.

See the previous page, next page, and complete command and settings index.