31.8 Sample sizes and bracketing the crossing
--sample-sizes accepts comma/space/semicolon-separated positive whole numbers. Values are sorted and deduplicated. With no list, the template subject count becomes the single N.
What the controls mean
- Use at least three useful sizes around the expected crossing for SSE interpolation.
- FIM scales continuous information and rounds upward; SSE interpolates observed point estimates.
- A coarse or noisy grid can yield a misleading crossing or only “not reached”.
The issued command is only the beginning of the audit trail. Always distinguish the reference model, the design template, the resolved scenario, the replicate-specific truth, the fitted result, and the test decision. A value can be correct at one layer and misinterpreted at another.
Command or settings pattern
--sample-sizes 30,45,60
Command-line values override settings-file values. Use a fresh folder for an analytical run; preserve the command, resolved settings, log, checksums, and row-level data. Defaults are versioned behavior, so a production protocol should state important values explicitly.
Interpretation and quality control
Plot intervals, confirm a broadly monotone trend, add points near the threshold, and implement feasible arm counts after rounding.
For a novice review, first confirm counts and labels, then inspect numerical values, then ask whether the assumptions represent the proposed clinical study. For an expert review, additionally reconcile aggregates from row-level output, reproduce a subset of trials, and compare the implementation with an independent reference where the claim requires it.
Common mistakes
- Supplying fractional or zero subjects
- Calling the smallest tested passing N the exact minimum
- Reporting a point estimate without its denominator, interval, method, and version
Minimum evidence to retain
- nlmx version, command,
.powerfile, resolved settings, seed, threads, and output checksums; - control stream, design dataset, EXT/COV or parameter sets, and their provenance;
- scenario table, replicate rows and failures, method summaries, plots, report, and interpretation;
- prespecified criteria, Monte Carlo target, validation scope, deviations, and reviewer decisions.
Navigation
See the previous page, next page, and complete command and settings index.