Documentation

27.3 The complete VPC workflow

nlmx vpc resolves inputs and settings, parses the model and data, computes population predictions, assigns filters/strata/bins, simulates replicated outcomes, calculates VPC and NPC summaries, and writes an auditable bundle. Each stage can fail for a different reason, so retain the transcript and read the first material warning.

The complete VPC workflow

Novice translation

This topic changes three practical decisions in a predictive-check review. First, input resolution uses the control stream plus --results-dir or explicit EXT/data/COV overrides. Second, population PRED is evaluated with ETA=0 and EPS=0; bins and prediction corrections are then defined from observed records. Third, simulation uses independent subject/replicate streams, followed by percentile, BLQ, and NPC calculations and report/plot export. Keep those decisions separate: one defines what is simulated or summarised, another controls how evidence is displayed, and the last controls what conclusion the evidence can support. A reviewer should be able to reproduce each decision from the resolved settings and numerical tables, not infer it from the appearance of the figure.

What to understand

  • Input resolution uses the control stream plus --results-dir or explicit EXT/data/COV overrides.
  • Population PRED is evaluated with ETA=0 and EPS=0; bins and prediction corrections are then defined from observed records.
  • Simulation uses independent subject/replicate streams, followed by percentile, BLQ, and NPC calculations and report/plot export.

Practical interpretation

A defensible run record contains the issued command, resolved vpc_settings.vpc, source checksums, seed, tables, report, plots, software version, and interpretation.

Evidence to retain

For the complete vpc workflow, retain the issued command, vpc_settings.vpc, the source model/data/result identifiers, seed and replicate count, the relevant CSV/JSON fields, warnings and notes, and the exact figure used for interpretation. Record any sensitivity run that changed the conclusion. If an option was selected after seeing the data, label that analysis exploratory. This evidence separates a reproducible diagnostic decision from a visual impression and lets another pharmacometrician check counts, transformations, exclusions, and uncertainty assumptions.

Common mistakes

  • Reviewing only the PNG
  • Reconstructing settings from memory
  • Ignoring warnings between simulation and writing

Page checklist

  • Resolve one run family
  • Archive settings and seed
  • Inspect tables before plots
  • Verify checksums

Further reading

See previous page, next page, complete VPC command and settings index.