Documentation

32.4 Confounding, reverse causation, and causal limits

Confounding, reverse causation, and causal limits
Executed or calculated Chapter 32 evidence

Randomised dose does not randomise individual exposure. Clearance, organ function, disease severity, adherence, treatment modifications, and prognostic factors can influence exposure and outcome. Exposure measured after treatment may also be affected by early response or toxicity, creating reverse causation or selection.

Core concepts

  • Draw a causal diagram before selecting adjustments. A variable that causes both exposure and outcome is a confounder; a mediator or collider can introduce bias if adjusted indiscriminately.
  • Dose can act as an instrument only under strong assumptions; simple E–R regression is not automatically a causal analysis.
  • Baseline covariates are generally safer adjustment candidates than postbaseline variables affected by treatment.

Keep five layers separate: the dose assignment, the individual exposure, the endpoint definition, the statistical estimand, and the clinical decision. A fitted curve connects exposure and endpoint within the analysed data; it does not automatically identify the effect of changing dose or exposure in another population.

Worked interpretation

A low-clearance patient can have high AUC and worse outcome because organ impairment raises both. An unadjusted positive exposure–toxicity slope may combine drug effect and physiology.

Read the causal map one arrow at a time

In the figure, randomised dose causes exposure, but clearance, adherence, renal function, disease severity, and treatment modification may also affect exposure. Some also predict response. Conditioning on individual exposure therefore breaks the protection provided by dose randomisation. If low clearance raises both AUC and toxicity risk, part of the observed AUC–toxicity trend is a patient-characteristic association.

Classify each candidate variable before adjustment: baseline common cause, pure prognostic factor, exposure predictor only, mediator, collider, or postbaseline consequence. Adjusting for a baseline common cause can reduce bias; adjusting for a mediator changes the estimand; adjusting for a collider can create bias. A data-driven p-value does not identify these roles.

Minimum sensitivities often include unadjusted, prespecified baseline-adjusted, dose-adjusted or dose-stratified, and alternative exposure-window analyses. Examine exposure overlap within dose and covariate strata. If certain exposure levels occur only in one frail subgroup, regression cannot manufacture exchangeability. Phrase the result as an association unless the causal intervention, assumptions, positivity, time ordering, and measurement process have been defended.

For a novice, translate every coefficient back to the endpoint scale. Name the starting exposure, ending exposure, predicted outcome at both, contrast, interval, and observed support. For categorical or survival endpoints, also show absolute probabilities or survival estimates because odds and hazard ratios can be hard to interpret clinically.

Quality control and scientific review

Report the adjustment set and rationale, dose–exposure overlap, residual confounding, temporal ordering, and sensitivity analyses.

Review sample size alone only after checking events, category cells, visit counts, placebo support, exposure overlap, exclusions, and missingness. A statistically precise curve can still be clinically irrelevant, confounded, extrapolated, or based on an endpoint definition that does not match the intended estimand.

Common mistakes

  • Selecting covariates only by significance
  • Claiming dose causality from exposure quartiles
  • Treating a significant exposure term as proof that the selected shape or causal story is correct

Evidence to retain

  • exposure definition, window, units, derivation, estimation uncertainty, and distribution by arm;
  • endpoint derivation, time origin/visit, analysis population, missing/censoring rules, and exclusions;
  • candidate models, covariate rationale, contrasts, selection criterion, diagnostics, failed/unstable fits;
  • effect estimates with intervals, observed range, sensitivity analyses, software version, settings, and checksums.

See the previous page, next page, and model and estimand catalogue.