27.36 Troubleshooting, limitations, and validation
Common failures include missing or ambiguous EXT/COV files, unsupported simulation code, F_FLAG during ICALL=4, invalid OMEGA/SIGMA, bad filter names, empty populations, invalid bins, and memory/disk pressure. Statistical limitations include sparse strata, bin dependence, multiplicity, finite Monte Carlo precision, and conditioning on one design.
Novice translation
This topic changes three practical decisions in a predictive-check review. First, start with a small fixed-estimate run to validate model/data/simulation logic, then expand replicates and features. Second, compare tables across thread counts or independent implementations when qualifying reproducibility. Third, cross-software validation should freeze inputs, seeds where comparable, percentile/bin definitions, tolerances, and expected differences in random streams. Keep those decisions separate: one defines what is simulated or summarised, another controls how evidence is displayed, and the last controls what conclusion the evidence can support. A reviewer should be able to reproduce each decision from the resolved settings and numerical tables, not infer it from the appearance of the figure.
What to understand
- Start with a small fixed-estimate run to validate model/data/simulation logic, then expand replicates and features.
- Compare tables across thread counts or independent implementations when qualifying reproducibility.
- Cross-software validation should freeze inputs, seeds where comparable, percentile/bin definitions, tolerances, and expected differences in random streams.
Practical interpretation
Document unsupported/excluded scenarios and never extrapolate VPC adequacy to populations, doses, schedules, or endpoints not simulated.
Evidence to retain
For troubleshooting, limitations, and validation, retain the issued command, vpc_settings.vpc, the source model/data/result identifiers, seed and replicate count, the relevant CSV/JSON fields, warnings and notes, and the exact figure used for interpretation. Record any sensitivity run that changed the conclusion. If an option was selected after seeing the data, label that analysis exploratory. This evidence separates a reproducible diagnostic decision from a visual impression and lets another pharmacometrician check counts, transformations, exclusions, and uncertainty assumptions.
Common mistakes
- Treating a technical success as validation
- Changing many settings at once
- Claiming cross-software identity without a protocol
Page checklist
- Triage first failing stage
- Use minimal reproducible run
- Qualify numerical definitions
- State evidence boundary
Further reading
See previous page, next page, complete VPC command and settings index.