32.8 Continuous endpoints: sigmoid Emax

Sigmoid Emax adds Hill coefficient γ: E0+Emax·C^γ/(EC50^γ+C^γ). γ=1 reduces to Emax; γ>1 makes a sharper transition, while γ<1 makes a more gradual early response. The added flexibility costs identifiability.
Core concepts
- EC50 and γ are positive and estimated on log scales.
- A narrow exposure band around the transition is needed to distinguish γ from EC50 and Emax.
- Very large γ approximates a step and often signals sparse transition data rather than a biological switch.
Keep five layers separate: the dose assignment, the individual exposure, the endpoint definition, the statistical estimand, and the clinical decision. A fitted curve connects exposure and endpoint within the analysed data; it does not automatically identify the effect of changing dose or exposure in another population.
Worked interpretation
In the executed continuous run, sigmoid Emax had slightly lower raw AIC but singular information and γ>10, so it was not rankable; Emax remained the defensible best model.
Hill coefficient and identifiability
The Hill coefficient controls transition sharpness. With γ=1, the model is ordinary Emax. With γ=2, the fraction of Emax rises from about 1% at 0.1×EC50 to 99% at 10×EC50; very large γ makes an almost discontinuous step. A sharp fitted step is credible only when many observations surround both sides of the transition.
Estimate and display curves from multiple starting values. Check whether log-EC50 and log-γ have finite standard errors, whether the information matrix is invertible, and whether bootstrap fits return to competing modes. The nested comparison against Emax adds one parameter, but a nominal likelihood-ratio improvement is not enough when the extra parameter lies in an unstable region.
In the executed example, sigmoid Emax obtained a slightly smaller raw AIC than Emax, yet its information was singular and Hill exceeded 10. It was therefore excluded from ranking. This is an important quality rule: numerical objective value is subordinate to estimability, data support, and reproducibility.
For a novice, translate every coefficient back to the endpoint scale. Name the starting exposure, ending exposure, predicted outcome at both, contrast, interval, and observed support. For categorical or survival endpoints, also show absolute probabilities or survival estimates because odds and hazard ratios can be hard to interpret clinically.
Quality control and scientific review
Use the nested likelihood-ratio comparison γ=1, but require estimable parameters and clinically plausible shape before choosing complexity.
Review sample size alone only after checking events, category cells, visit counts, placebo support, exposure overlap, exclusions, and missingness. A statistically precise curve can still be clinically irrelevant, confounded, extrapolated, or based on an endpoint definition that does not match the intended estimand.
Common mistakes
- Selecting the smallest raw AIC despite singular information
- Interpreting a huge Hill estimate literally
- Treating a significant exposure term as proof that the selected shape or causal story is correct
Evidence to retain
- exposure definition, window, units, derivation, estimation uncertainty, and distribution by arm;
- endpoint derivation, time origin/visit, analysis population, missing/censoring rules, and exclusions;
- candidate models, covariate rationale, contrasts, selection criterion, diagnostics, failed/unstable fits;
- effect estimates with intervals, observed range, sensitivity analyses, software version, settings, and checksums.
Navigation
See the previous page, next page, and model and estimand catalogue.