37.27 Power-and-sample-size settings: purpose, structure, and workflow
.power is the settings format for power. It defines model-informed design scenarios, SSE or FIM calculations, tests, estimation behavior, performance criteria, resumption and retained outputs. The template snapshot used here was generated by nlmx 4.16.2; its SHA-256 is 3b0787cd0e8826a79b462598bdc5b08721a42d61264d76105ae94a715f3e2ec0.
Why this file matters
Power is meaningful only for the exact effect, null, design, missingness, fit success and decision rule represented by the configuration. Treat the file as controlled analysis source. A reviewer should be able to connect each active value to a design decision, data convention, method choice, output requirement or operational guardrail.
Generate and begin safely
nlmx power --print-config study.power
nlmx power -c study.power --output disposable-review
For .covar, generate the reference with nlmx schema --format toml and save it with the required extension. For every format, compare command-specific help before relying on the generic example above; commands differ in positional inputs, validation modes and whether --output is appropriate.
Template map
The snapshot represents 61 unique dotted key paths across 9 tables or top-level groups. Commented assignments are possibilities or examples; uncommented assignments form the generated example. The next page catalogs every represented key.
| Table | Unique keys represented | Review focus |
|---|---|---|
input |
5 | values and interactions inside this settings group |
analysis |
6 | values and interactions inside this settings group |
schedule[] |
13 | values and interactions inside this settings group |
test[] |
10 | values and interactions inside this settings group |
estimation |
6 | values and interactions inside this settings group |
sse |
7 | values and interactions inside this settings group |
fim |
4 | values and interactions inside this settings group |
criteria |
6 | values and interactions inside this settings group |
output |
4 | values and interactions inside this settings group |
Important interactions
- Distinguish SSE empirical power from FIM asymptotic power.
- Include convergence failures in the reported denominator and sensitivity analysis.
- Test type-I error when possible rather than reporting power alone.
- Resume only when the scenario fingerprint matches the original run.
Novice workflow
First identify the input population and artifact version. Second, delete or leave commented every option you do not intend to control. Third, edit one table at a time and keep short comments explaining study-specific values. Fourth, run into a new disposable folder and verify resolved inputs, paths, warnings and output count. Fifth, compare the result with the scientific question and expected behavior. Finally, retain the settings, command transcript and reviewed outputs together.
What validation can and cannot prove
Parsing proves that TOML syntax and recognized keys are acceptable. Command validation may prove that referenced data and values satisfy implemented checks. Neither proves that the selected population, endpoint, method, threshold or model is scientifically justified. That judgment belongs in the analysis plan and review record.
The exact generated snapshot is available at documents/ch37/reference/templates/nlmx.power.
Navigation
See the previous page, next page, and complete settings reference.