22.33 Worked example: frozen and SCM on known covariate effects
The deterministic Chapter 22 dataset has 60 subjects and 480 oral PK observations. True clearance depends on WT with exponent 0.75 and EGFR with exponent 0.55; volume depends on WT with exponent 1.0. SEX has no effect. The base FOCE-I model omits all covariates.
nlmx cov --model-dir documents/ch22/results/base_fit `
--run-stem run22 `
--covariates "CL=WT,EGFR,SEX;V=WT,SEX" `
--method frozen --seed 22048 `
--output documents/ch22/results/frozen
Frozen selection retained V–WT, rejected both SEX effects, and classified CL–WT and CL–EGFR as uncertain: both were highly significant univariately but failed the strict conditional backward retention threshold. Its final refit contained V–WT exponent 0.9975 and OFV −1123.325.
SCM used the identical scope:
nlmx cov --model-dir documents/ch22/results/base_fit `
--run-stem run22 --covariates "CL=WT,EGFR,SEX;V=WT,SEX" `
--method scm --scm-direction both `
--scm-candidates-per-step 3 --seed 22048 `
--output documents/ch22/results/scm
SCM retained V–WT (estimated 1.010), CL–WT (0.727), and CL–EGFR (0.578), closely recovering truth, and rejected both SEX relationships. The joint final OFV was −1157.813, 75.252 below the base. Backward removal p-values were 9.84e-11, 2.81e-6, and 6.52e-5 respectively.
The contrast illustrates method behavior. Frozen local conditional thresholds were conservative for the two CL effects in this finite nonlinear example; SCM refits recovered them. Neither result should be generalized from one simulation. Preserve both evidence bundles and confirm the SCM draft fit/diagnostics.
Common mistakes
- Calling frozen uncertain relationships false effects.
- Treating one simulation as comparative validation.
- Comparing final OFV when retained sets differ without context.
- Reporting screening estimates instead of joint refit values.
- Forgetting that the truth is known only in this synthetic example.
Checklist
- Reproduce identical scope, base, seed, and policies.
- Verify method-specific selection trace.
- Compare classifications and final refit estimates.
- Relate estimates to known truth cautiously.
- Confirm draft convergence and diagnostics.
Further reading
Open the frozen report, SCM report, and method map.