33.13 Binary, ordinal, count, TTE, and longitudinal controls
Endpoint-specific keys change coding and likelihood: positive for binary; ordered levels for ordinal; offset and dispersion for counts; time/event values, KM groups, reference, landmarks and risk times for TTE; visit, baseline, central summary and error bars for longitudinal.
Command or configuration pattern
nlmx er -c endpoint-specific.er
The relevant controls are: positive/proportion_ci; levels; offset/dispersion; time/event/event_value/km_*; visit/baseline/change/central/error. Use the complete command and settings index for accepted values, defaults, CLI mappings, and settings-only controls.
A reliable operating sequence
- State the endpoint estimand, exposure metric/window/units, analysis population, adjustment set, and clinically useful contrast.
- Reconcile input rows, subjects, arms, exposure availability, endpoint information, and all endpoint-specific fields.
- Run the smallest useful specification first; inspect exclusions and eligible models before adding subgroups, selection, or bootstrap.
- Read absolute predictions and observed support alongside relative effects, information criteria, p-values, and diagnostics.
- Archive the command,
.erfile, mutated/used data, exclusions, transcript, tables, plots, report, version, and checksums.
How to read and review the result
Treat these as endpoint definitions, not styling. Verify positive codes and category order; offset units and positivity; event/censoring rules; visit windows and baseline derivation. Defaults cannot infer the clinical estimand. Chapter 32 explains how each model scale changes interpretation.
For a novice, the safest reading order is er_summary.txt → er_analyses.csv → the analysis-specific exclusions and model table → effects/predictions → diagnostic plots → row-level data → report.html. The report is a presentation layer; the CSV/JSON files and transcript are the audit layer.
Quality-control questions
- Did the number of analysed subjects, events, categories, exposure groups, and visits match the specification?
- Were placebo, active zeros, missing values, filters, repeated rows, categories, offsets, censoring, and covariate references handled as intended?
- Were ineligible fits retained and explained rather than silently dropped or allowed to win?
- Does the reported contrast stay inside exposure support, and are its units and endpoint direction clear?
- Do diagnostics and sensitivities support the same decision, and are causal and transportability limits explicit?
Common failure modes
- Treating the best criterion or smallest p-value as a clinical conclusion.
- Reading an odds, rate, or hazard ratio without its exposure contrast and absolute outcome context.
- Overwriting an evidence directory before preserving the prior settings, log, and checksums.
Navigation