11.2 What qc-data can and cannot prove

Automated QC is strongest at finding contradictions, unreadable structures and values outside declared expectations. It cannot establish that a plausible value is true.

What it can establish

Within the configured rules, qc-data can show that:

  • the physical file and fields can be parsed;
  • required columns exist and have usable names;
  • special items are numeric and internally consistent;
  • IDs form blocks and TIME is ordered;
  • dose, observation and covariate patterns meet chosen thresholds;
  • the intended $DATA IGNORE and suggested $INPUT are compatible with the file;
  • every check has an explicit status and retained evidence.

What it cannot establish

It cannot confirm that subject 17 truly received 100 mg, that a concentration was transcribed from the correct assay result, that a missing sample was missing for the documented reason, or that the study complied with the protocol. It cannot choose a scientifically appropriate model or certify equivalence with another software package.

QC validation boundary

Figure 11.3. Automated consistency checks operate inside a boundary. Truth, intent and scientific appropriateness require external evidence and expert review.

Plausible is not correct

A weight of 70 kg passes a range check whether it belongs to the subject or was copied from another row. Conversely, a weight of 4 kg may be correct in a neonatal study even though an adult-oriented expectation would flag it. Thresholds encode context; they do not manufacture truth.

READY is scoped language

READY means no configured check produced a failure or warning. READY WITH WARNINGS means no failure remains but warnings need review. NOT READY means at least one failure exists. These verdicts summarize the configured automated review; they do not replace data-management approval or scientific sign-off.

Common mistakes

  • Writing “dataset validated” when only automated QC was run.
  • Treating a range violation as proof the value is wrong.
  • Treating a range pass as proof the value is correct.
  • Claiming cross-software accuracy from a clean QC report alone.

Checklist

  • State the purpose and scope of the QC.
  • Link every correction to authoritative evidence.
  • Describe READY as a configured automated result.
  • Retain independent data-management and scientific review.

Further reading

See threshold customization, the remediation loop and the planned Chapter 42 validation framework.