11.2 What qc-data can and cannot prove
Automated QC is strongest at finding contradictions, unreadable structures and values outside declared expectations. It cannot establish that a plausible value is true.
What it can establish
Within the configured rules, qc-data can show that:
- the physical file and fields can be parsed;
- required columns exist and have usable names;
- special items are numeric and internally consistent;
- IDs form blocks and TIME is ordered;
- dose, observation and covariate patterns meet chosen thresholds;
- the intended
$DATA IGNOREand suggested$INPUTare compatible with the file; - every check has an explicit status and retained evidence.
What it cannot establish
It cannot confirm that subject 17 truly received 100 mg, that a concentration was transcribed from the correct assay result, that a missing sample was missing for the documented reason, or that the study complied with the protocol. It cannot choose a scientifically appropriate model or certify equivalence with another software package.
Figure 11.3. Automated consistency checks operate inside a boundary. Truth, intent and scientific appropriateness require external evidence and expert review.
Plausible is not correct
A weight of 70 kg passes a range check whether it belongs to the subject or was copied from another row. Conversely, a weight of 4 kg may be correct in a neonatal study even though an adult-oriented expectation would flag it. Thresholds encode context; they do not manufacture truth.
READY is scoped language
READY means no configured check produced a failure or warning. READY WITH WARNINGS means no failure remains but warnings need review. NOT READY means at least one failure exists. These verdicts summarize the configured automated review; they do not replace data-management approval or scientific sign-off.
Common mistakes
- Writing “dataset validated” when only automated QC was run.
- Treating a range violation as proof the value is wrong.
- Treating a range pass as proof the value is correct.
- Claiming cross-software accuracy from a clean QC report alone.
Checklist
- State the purpose and scope of the QC.
- Link every correction to authoritative evidence.
- Describe READY as a configured automated result.
- Retain independent data-management and scientific review.
Further reading
See threshold customization, the remediation loop and the planned Chapter 42 validation framework.