41.11 Case 3: which structure does the data support?
What you will learn
- Read a
screenreport: the candidate table, the likelihood-ratio tests, the recommendation and the cautions.- Explain why BIC and the likelihood-ratio test can agree and still leave a question open.
- Interpret ill-conditioned, not converged and shrinkage flags attached to a recommended model.
- Decide what a recommendation means when the model it names carries a warning.
Prerequisites: 41.10 and Chapter 17, structural screening.
The question: which structural model does the data support: one, two or three compartments; with or without a lag; linear or saturable elimination?
The evidence: three Chapter 17 bundles: oral_distribution (18 subjects, 180 observations), oral_lag (18 subjects, 216 observations) and nonlinear_mm (30 subjects at three dose levels, IV bolus, 300 observations). Each has a .screen settings file, a screen_summary.txt and a model_comparison.csv.
What a screen does
screen fits a family of candidate structures, nested one in the next, starting each from the previous model's final estimates (the first from autoinit), and compares them on the same data. Each candidate is judged on fit (OFV, AIC, BIC with a small-sample penalty), estimability (relative standard errors, condition number) and shrinkage. The model recommended is the best on the chosen criterion among those that pass the checks (RSE ≤ 50 %, condition number ≤ 1000, as set in the screen file).
Screen 1: peripheral compartments (oral_distribution)
model OFV k BIC ΔBIC weight cov max RSE max sh flags
1cmt_abs -424.93 6 -398.38 263.05 0.000 ok 3% 5% –
2cmt_abs -682.93 8 -646.00 15.43 0.000 ok 5% -1% ill-conditioned
3cmt_abs -708.75 10 -661.43 0.00 1.000 ok 43% 7% ill-conditioned
Likelihood-ratio tests of nested models:
| Comparison | ΔOFV | df | p |
|---|---|---|---|
| 1 → 2 compartments | 258.00 | 2 | < 0.0001 |
| 1 → 3 compartments | 283.82 | 4 | < 0.0001 |
| 2 → 3 compartments | 25.82 | 2 | < 0.0001 |
Everything points the same way. The critical ΔOFV for two degrees of freedom at p = 0.01 is 9.21, and 25.82 is almost three times that; the ΔBIC of 15.4 is "strong evidence". The same data analysed with the likelihood-ratio criterion (the bundle oral_distribution_lrt, identical but for criterion = "lrt") selects 3cmt_abs through the stepwise test.
And yet the recommendation carries three warnings.
- The recommended model is ill-conditioned, κ = 32 863, against a limit of 1000 in the settings. A condition number that large says the parameter estimates are highly correlated or poorly identified; some combinations of parameters are almost undetermined.
- Its largest relative standard error is 43 % (THETA 5), close to the 50 % ceiling.
- The runner-up is also flagged (κ = 2370).
The autoinit notes in the same screen add a fourth observation: "18 of 18 subjects fitted are clearly biexponential: a two-compartment model is likely needed." The data's own subject-level behaviour points to two compartments, while the likelihood continues to reward a third. Ten samples per subject over 0.25–48 h, one dose level, 18 subjects: the information to separate three exponentials is thin, and BIC cannot tell a third compartment from a tail of unmodelled variability.
Screen 2: the lag time (oral_lag)
model OFV k BIC ΔBIC cov max RSE max sh flags
1cmt_abs -182.75 6 -155.47 346.75 ok 3% 73% –
2cmt_abs -183.45 8 -145.41 356.80 ok 22% 72% ill-conditioned
1cmt_abs_lag -534.87 7 -502.22 0.00 ok 3% 69% ill-conditioned (κ = 4.5e6)
2cmt_abs_lag -538.23 9 -494.82 7.39 -- 3% 70% not converged
The lag time is the decisive structural element: adding it improves the OFV by 352.1 (1 df), while a second compartment, with or without a lag, buys only 0.70 (without) or 3.36 (with) for 2 degrees of freedom (p = 0.71 and p = 0.19). The recommended model is the one-compartment with lag. The caution is shrinkage: 69 % on the ETA of KA. When 69 % of the random effect's variance is shrunk toward zero, the individual estimates carry little information about each subject, and diagnostics based on them (ETA plots, covariate screens) are not reliable. The report advises "consider fewer random effects". The κ of 4.5 million, the largest in the chapter, says that some parameter combination is essentially undetermined. The program tells the analyst, plainly: this is the best of four, and it is not a well-conditioned model.
The fourth candidate, 2cmt_abs_lag, has a lower OFV but did not converge, so it is not eligible. Its place in the table is information: the data do not give a stable answer for that structure.
Screen 3: saturable elimination (nonlinear_mm)
model OFV k BIC ΔBIC max RSE flags
1cmt_noabs 670.74 6 695.75 578.54 15% –
1cmt_noabs_mm 210.84 8 247.26 130.05 4% –
1cmt_noabs_tmdd 75.09 9 117.21 0.00 3% not converged; ill-conditioned (κ = 24045)
Here the dose-proportionality check (the same power-model idea as page 41.8, applied to dose-normalised AUC) already says that the elimination is saturable:
dose-normalised AUC vs dose over 3 levels (10 to 1000), 20 subjects:
slope 0.62 (SE 0.03, p < 0.0001) — exposure rises more than proportionally
The program recommends the Michaelis–Menten model (VMAX 2.92, KM 29.4 in the initial values for the next model) and says why the target-mediated-drug-disposition model, which has a much lower BIC (ΔBIC = 130), was passed over: not converged, ill-conditioned (κ = 24045). The note ends with an instruction to the analyst: "review its fit before settling on 1cmt_noabs_mm". It also reports that the clearance in the three dose groups is 4.13×, 0.66× and 0.37× the overall value, a pattern that is the saturable elimination itself, not an error in coding. Fits that pool all dose levels with a linear model must show exactly this.
How to read a recommendation
| Signal | What it says | What you do |
|---|---|---|
| ΔBIC > 10 and LRT significant | strong statistical support | necessary, not sufficient |
| ill-conditioned | parameters poorly separated | check whether a simpler model is nearly as good |
| not converged | the optimiser did not settle | the model is not a candidate; the fit is information about the data |
| shrinkage ≥ 30 % on an ETA | that random effect is not informed | consider removing it before using ETA-based diagnostics |
| max RSE near 50 % | one parameter barely determined | fix it, remove it, or get more data |
The recommendation is a function of the data, the candidate list and the criterion. Change any of the three and the answer can change. That is why the screen file records all of them.
The decision
| Question | Evidence | Decision | Reversible? |
|---|---|---|---|
Which structure for oral_distribution? |
BIC and LRT favour 3 compartments; κ = 32 863, RSE 43 %; autoinit says biexponential | Carry 2 and 3 compartments to the fit stage; decide on diagnostics (41.12) | yes |
Which for oral_lag? |
lag time ΔOFV 352; second compartment p = 0.19 | One compartment with lag; reduce random effects (shrinkage 69 %) | yes |
Which for nonlinear_mm? |
slope 0.62; MM ΔBIC vs linear 448.5; TMDD not converged | Michaelis–Menten; revisit TMDD only with more data or a reparametrisation | yes |
What this case does not show
It does not show the data-generating truth. The group label in the oral_distribution file reads "Oral 2cmt", which suggests a two-compartment generator, but this chapter treats the label as a hint, not as evidence: the point of the page is how an analyst decides when the truth is not known.
Review checklist
- Did you read the flags on the recommended model, not only its name?
- Is a not-converged candidate treated as information rather than discarded silently?
- Do you know what the screen file said about the criterion and the checks?
- Have you written down which alternatives remain open?
Navigation